Skip to main content
Schneider Electric MGN60513 — 1-Pole MCB (DIN Rail)

MGN60513 C60N MCB, 1P 20A Curve D, 10 kA

MPNMGN60513
Obsolete

Schneider Electric C60N Multi9 miniature circuit breaker, MGN60513, 1P, 20 A, curve D, 10 kA breaking capacity at 240 V AC, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60513 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60N
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60513 — Electrical & Protection
ParameterValue
Rated current (In)20 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60513 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60513 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60513 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The MGN60513 is a C60N miniature circuit breaker from Schneider Electric's Multi9 range, a single-pole thermal-magnetic MCB rated 20 A at 50 °C per EN/IEC 60947-2. The 10 kA Icu at 240 V AC (phase to neutral) tells you it can safely interrupt a fault up to that level without failing; the Ics (service breaking capacity) is 75 % of that, or 7.5 kA, meaning after one high-level fault it's still rated to clear a second one at that lower level. That's a solid spec for a distribution panel feeding motor circuits or general branch loads.

Snaps onto 35 mm symmetrical DIN rail (EN 60715). At 18 mm wide (2 x 9 mm pitches), it takes one module slot in a standard enclosure — no extra space needed for the single pole. Depth is 73 mm, height 81 mm.

Listed as current production (active lifecycle stage). The C60N series is a long-running Multi9 staple.

Frequently asked questions

What is the breaking capacity of MGN60513?

10 kA Icu at 240 V AC (phase to neutral) per EN/IEC 60947-2, with an Ics of 7.5 kA (75 %) at the same voltage.

MPN
MGN60513