Skip to main content
Schneider Electric MGN60519

MGN60519 C60N MCB, 2A D Curve 2P 20kA, 440V AC

MPN MGN60519
Obsolete

Schneider Electric Multi9 C60N, MGN60519, miniature circuit breaker, 2 A rated, D curve, 2 poles, 20 kA Icu at 240 V AC, 440 V AC rated voltage.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60519 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

MGN60519 additional specifications
ParameterValue
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60519 is a C60N miniature circuit breaker from the Multi9 range, rated 2 A with a D tripping curve, 2 poles, and a 20 kA Icu breaking capacity at 240 V AC. It's a thermal-magnetic MCB built to EN/IEC 60947-2, which means it's rated for distribution duty in industrial control panels — not just residential final circuits. The 73 mm depth and 81 mm height are standard for the C60 footprint, so it slots into an existing Multi9 panel layout without re-spacing.

Breaking capacity and selectivity — the real-world limits

That's the figure a site electrical engineer cares about for selectivity coordination downstream. At 415 V the Icu drops to 10 kA, and at 440 V to 6 kA. For a 2 A D-curve breaker, the 10 kA at 415 V is typical for motor branch circuits on a 400 V supply; the 6 kA at 440 V is the ceiling for a 440 V line-to-line system.

IP20 finger-safe terminals. Mechanical durability 20,000 cycles, electrical 10,000 cycles. The MCB is suitable for isolation — it has a contact position indicator and ON/OFF local signaling. Earth-leakage protection requires a separate block; this is the plain MCB, not an RCBO.

MPN
MGN60519