Schneider Electric MGN60522 — 2-Pole MCB (DIN Rail)

MGN60522 C60N MCB, 2P D-curve 10 A, 20 kA Icu

MPNMGN60522
Obsolete

Schneider Electric C60N Multi9 miniature circuit-breaker, MGN60522, 2-pole, D-curve, 10 A rated current, 20 kA Icu at 240 V AC, thermal-magnetic trip, DIN-rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60522 — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN60522 — Electrical
ParameterValue
Rated current [In]10 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
MGN60522 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN60522 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Terminal tightening torquePower circuit: 2 N.m
Comb busbar / distribution block compatibilityTop or bottom: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN60522 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
MGN60522 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

D-curve trip and what it means for the panel

The MGN60522: The D-curve magnetic trip fires at 12 x In ±20 %, meaning the instantaneous trip threshold for this 10 A breaker is nominally 120 A. For audit purposes, the magnetic tripping limit is per the datasheet: 12 x In ±20 %. The utilisation category is Category A per EN/IEC 60947-2, which means it is not intended for current-limiting performance under short-circuit conditions — the breaker clears the fault but does not restrict the let-through energy to the degree a Category B (current-limiting) device would. This matters when coordinating with downstream equipment.

The 2-pole footprint occupies 4 x 9 mm pitches (36 mm wide), 81 mm tall, 73 mm deep. Pollution degree 3 per EN/IEC 60947-2 — suitable for industrial environments where conductive pollution may occur.

Frequently asked questions

What is the breaking capacity of MGN60522?

The breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V AC, and 6 kA at 440 V AC, all per EN/IEC 60947-2.

What is the rated current and curve of MGN60522?

The rated current is 10 A at 50 °C per EN/IEC 60947-2, with a D-curve thermal-magnetic trip unit.

MPN
MGN60522