Schneider Electric MGN60526 — 2-Pole MCB (DIN Rail)

MGN60526 C60N Miniature Circuit-Breaker, 32 A, 2P, D Curve,

MPNMGN60526
Obsolete

Schneider Electric C60N Multi9 miniature circuit-breaker, MGN60526, 2-pole, D curve, 32 A rated current, 10 kA Icu at 415 V AC, thermal-magnetic trip, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60526 — Identification
ParameterValue
Product nameC60
Product rangeC60
Series / familyMulti9
Device short nameC60N
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN60526 — Electrical
ParameterValue
Rated current [In]32 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Network type (AC/DC)AC
Network frequency50/60 Hz
MGN60526 — Protection
ParameterValue
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu)20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN60526 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Terminal connectionsTunnel type terminals1.5...35 mm² flexible without cable end Tunnel type terminals1.5...35 mm² flexible with cable end Tunnel type terminals1.5...35 mm² rigid
Terminal tightening torquePower circuit: 3.5 N.m
Comb busbar / distribution block compatibilityTop or bottom: YES
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN60526 — Environmental
ParameterValue
Operating temperature range-30...70 °C
Storage temperature range-40...80 °C
MGN60526 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The MGN60526: Breaking capacity is listed at 20 kA Icu at 240 V AC phase-to-phase, 10 kA Icu at 415 V AC, and 6 kA Icu at 440 V AC — all per EN/IEC 60947-2. The rated service breaking capacity (Ics) is 75 % of Icu at each voltage level, so at 415 V it can clear 7.5 kA and still be usable afterward — that 75 % ratio is standard for Category A breakers (no intentional short-time delay). Two protected poles, 2P configuration, with suitability for isolation confirmed per EN/IEC 60947-2 — meaning the open contacts provide a visible air gap and the breaker is marked to serve as a disconnecting means. The contact position indicator (ON/OFF indication on the toggle) gives a positive visual confirmation of the contact state, which matters when you are locking out a circuit for maintenance.

Mounts on a 35 mm symmetrical DIN rail — the standard EN 60715 profile — occupying 4 x 9 mm pitches (36 mm wide). The 73 mm depth and 81 mm height fit within the envelope of a standard distribution board or enclosure, but check the gland-plate clearance if the panel has a shallow door or a rear-mounted busbar system. Tunnel-type terminals accept 1.5 to 35 mm² conductors — flexible with or without ferrule, or solid. That 35 mm² top end means it can take a fairly heavy feeder cable for a 32 A circuit, but the terminal design is fixed, not a lug or ring-terminal type, so plan your cable termination method accordingly.

The C60N series has been a workhorse in the Multi9 range for years, and the D-curve variant (MGN60526) is the one you reach for when the load has a high inrush — motor starters, small transformers, discharge lighting. If you are holding a legacy panel that uses an older C60N D32, this is the direct replacement; no adapter or busbar rework needed, provided the DIN-rail pitch and busbar spacing match.

The breaker is designed for distribution duty (Category A, no intentional delay), with an electrical endurance of 10,000 cycles and mechanical endurance of 20,000 cycles. Earth-leakage protection requires a separate block (Vigi or similar) — there is no integral RCD in this unit.

Frequently asked questions

What is the breaking capacity of MGN60526 at 415 V?

The MGN60526 has a breaking capacity of 10 kA Icu at 415 V AC 50/60 Hz phase-to-phase, conforming to EN/IEC 60947-2. The rated service breaking capacity (Ics) at that voltage is 7.5 kA (75 % of Icu).

What is the D curve on this MCB?

The D curve means the magnetic trip threshold is 12 x In (±20 %), so for the 32 A rated current the instantaneous trip point is approximately 384 A. This is designed for loads with high inrush current such as motors, transformers, and discharge lighting.

Where can I buy MGN60526 and what is the lead time?

The MGN60526 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What compliance documentation does MGN60526 carry?

The MGN60526 is certified to EN/IEC 60947-2, with pollution degree 3, IP20 protection, and suitability for isolation. It is part of the Schneider Electric Multi9 range; full compliance documentation (declaration of conformity, CE marking) is available from the manufacturer.