Schneider Electric MGN60527

MGN60527 C60N MCB, D Curve 40 A 2P, 20 kA at 240 V

MPN MGN60527
Obsolete

Schneider Electric Multi9 C60N series, MGN60527 miniature circuit breaker, D curve, 40 A rated, 2 poles, 20 kA Icu at 240 V AC, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60527 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60527 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

MGN60527 C60N — 40 A D Curve MCB, 2-Pole

The MGN60527 is a C60N miniature circuit breaker from the Multi9 range, rated 40 A at 50 °C with a D tripping curve, 2 poles, and a 20 kA Icu breaking capacity at 240 V AC phase-to-phase. Breaking capacity is 20 kA Icu at 240 V AC, 10 kA at 415 V, and 6 kA at 440 V, all per EN/IEC 60947-2. The service breaking capacity (Ics) is 75 % of Icu at each voltage level — 15 kA at 240 V, 7.5 kA at 415 V, 4.5 kA at 440 V — which tells you the breaker can be reclosed after clearing a fault at those levels without immediate replacement. Rated operational voltage is 440 V AC, and the unit is suitability for isolation certified per the same standard. The contact position indicator gives a visual ON/OFF confirmation at the toggle.

Depth is 73 mm, height 81 mm. Tightening torque for the power circuit is 3.5 N·m. Pollution degree 3 per EN/IEC 60947-2 — suitable for industrial enclosures where conductive pollution may occur. IP20 finger-safe protection on the front face. Earth-leakage protection requires a separate block (not integrated). The breaker itself provides thermal-magnetic overcurrent protection on both poles.