Schneider Electric MGN60611 — 1-Pole MCB (DIN Rail)

Schneider Electric MGN60611 C60H MCB, 4A Curve C, 1P, 15kA

MPNMGN60611
Obsolete

Schneider Electric Multi9 C60H, MGN60611, miniature circuit breaker, 4 A rated current, C-curve, 1-pole, 15 kA breaking capacity at 240 V AC, thermal-magnetic trip, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60611 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60611 — Electrical & Protection
ParameterValue
Rated current (In)4 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral 415 V AC 50/60 Hz phase to phase
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu / AIR)15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 24 kA Icu at 60 V DC phase to phase conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60611 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60611 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60611 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The Schneider Electric MGN60611 is a C60H miniature circuit breaker from the Multi9 range, rated 4 A at 50 °C with a C-curve trip characteristic.

Rated Icu of 15 kA at 240 V AC phase-to-neutral and 24 kA at 60 V DC phase-to-phase (both per EN/IEC 60947-2). The Ics at 240 V AC is 7.5 kA (50%), meaning it can be reclosed after clearing a fault at that level. For DC applications, the 24 kA Ics at 100% is notable — it clears DC faults at full rating without derating the service capacity. That 24 kA DC rating is the figure to check against your battery bank or DC bus fault current.

Installation and wiring

The toggle gives local ON/OFF indication. IP20 finger-safe terminals — standard for enclosed distribution boards.

Listed as current production.

Frequently asked questions

Where can I buy MGN60611 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is MGN60611's breaking capacity at 240 V AC?

The rated Icu is 15 kA at 240 V AC phase-to-neutral per EN/IEC 60947-2.

What compliance documentation does Schneider Electric provide for MGN60611?

The MCB is certified to EN/IEC 60947-2, with pollution degree 3 and suitability for isolation. The specific RoHS, REACH, or UL documentation should be confirmed at order time from the manufacturer's compliance portal.