Schneider Electric MGN60615 — 1-Pole MCB (DIN Rail)

MGN60615 C60H MCB, 20A 1P C-Curve, 15kA/24kA Breaking Capaci

MPNMGN60615
Obsolete

Schneider Electric C60H Multi9 series, MGN60615, 1-pole miniature circuit breaker, 20 A rated, C-curve, 15 kA Icu at 240 V AC, 24 kA Icu at 60 V DC, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60615 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60615 — Electrical & Protection
ParameterValue
Rated current (In)20 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral 415 V AC 50/60 Hz phase to phase
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu / AIR)15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 24 kA Icu at 60 V DC phase to phase conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60615 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60615 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60615 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The MGN60615 is a 1-pole C60H miniature circuit breaker from the Multi9 range, rated 20 A at 50 °C per EN/IEC 60947-2. The C-curve (magnetic trip at 8.5 x In, +/- 20 %) means it holds brief motor inrush but trips fast on a hard short; it's the standard choice for general-purpose distribution and mixed resistive-inductive loads in a control panel. Breaking capacity is 15 kA Icu at 240 V AC phase-to-neutral, and 24 kA Icu at 60 V DC phase-to-phase. The 24 kA DC rating is unusually high for a 1-pole 20 A MCB; it means this breaker handles battery-bank or rectifier-fed DC bus faults where most residential-grade MCBs would fail.

Snaps onto a 35 mm symmetrical DIN rail, 18 mm wide (2 x 9 mm pitches). That 18 mm width is the standard single-module footprint for a 1-pole MCB — it occupies one slot in a distribution board or enclosure rail. Tunnel terminals accept 1 to 25 mm² rigid or flexible wire; strip 14 mm and torque to 2 N·m.

Suitable for isolation — the contact position indicator shows ON/OFF status visually. Mechanical durability is 20,000 cycles; electrical durability 10,000 cycles at rated load. Ambient operating range is -30 to 70 °C, storage -40 to 80 °C. Earth-leakage protection requires a separate block (not built-in).

Frequently asked questions

What is MGN60615's breaking capacity at 240 V AC?

15 kA Icu at 240 V AC phase-to-neutral per EN/IEC 60947-2. Service breaking capacity (Ics) is 7.5 kA at the same voltage.