MGN60629 C60H MCB, 2P 25A C-Curve, 30 kA at 240 V AC

MPN MGN60629
Obsolete

Schneider Electric Multi9 C60H, C60, MGN60629, miniature circuit-breaker, 2P, 25 A, C curve, 30 kA Icu at 240 V AC, 125 V DC rated.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60629 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase 415 V AC 50/60 Hz phase to phase
Breaking capacity30 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 25 kA Icu at 125 V DC phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60629 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

Certified DC and AC fault interruption — MGN60629

The MGN60629 is a C60H miniature circuit breaker from the Multi9 range, configured as a 2-pole unit with a C-curve trip characteristic and a 25 A rated current at 50 °C, certified to EN/IEC 60947-2. Its headline breaking capacity reaches 30 kA Icu at 240 V AC phase-to-phase and 25 kA Icu at 125 V DC phase-to-phase, both conforming to EN/IEC 60947-2 — the DC rating is the figure that governs fit for battery-bank or DC-bus protection, not the AC number.

The 125 V DC rating at 25 kA Icu is the more restrictive figure — verify the DC source's prospective short-circuit current does not exceed 25 kA. The C-curve magnetic trip at 8.5 x In (±20 %) means the breaker holds through moderate inrush from motor or transformer loads but trips promptly on a hard short. At 240 V AC, Ics is 50 % of Icu (15 kA), still adequate for most secondary-distribution faults but a consideration if the breaker must clear repeated high-energy faults on the same installation.

The 2-pole body occupies 4 x 9 mm pitches (36 mm width) and a depth of 73 mm, leaving clearance for tunnel-type terminals accepting 1 to 25 mm² rigid or flexible conductors. The toggle provides local ON/OFF indication with a contact position indicator — no auxiliary contact needed for visual status.