Skip to main content
Schneider Electric MGN60865 — 1-Pole MCB (DIN Rail)

MGN60865 C60N MCB, 1P C-curve 4 A, 10 kA

MPNMGN60865
Obsolete

Schneider Electric Multi9 C60N series, MGN60865 miniature circuit-breaker, 1P, C-curve, 4 A rated current, 10 kA breaking capacity at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60865 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60N
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60865 — Electrical & Protection
ParameterValue
Rated current (In)4 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60865 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60865 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60865 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The MGN60865 is a Schneider Electric C60N miniature circuit-breaker from the Multi9 range, single-pole, C-curve, rated 4 A at 50 °C per EN/IEC 60947-2. It breaks 10 kA Icu at 240 V AC phase-to-neutral and 3 kA Icu at 415 V AC, making it suitable for distribution boards where the fault current stays within those limits. The C-curve magnetic trip triggers at 8.5 x In ±20 %, so it handles moderate inrush from small motors or transformers without nuisance tripping.

Snaps onto 35 mm symmetrical DIN rail, occupies 2 x 9 mm pitches (18 mm wide). Tunnel terminals accept 1…25 mm² rigid or flexible wire; strip 14 mm and torque to 2 N·m. The 73 mm depth leaves clearance for standard gland plates and comb busbars — top or bottom feed is supported.

Rated for isolation with a visible contact-position indicator. Electrical durability is 10,000 cycles; mechanical durability 20,000 cycles. Ambient operating range -30…70 °C, storage -40…80 °C.

Frequently asked questions

What is MGN60865's breaking capacity?

10 kA Icu at 240 V AC and 3 kA Icu at 415 V AC, both phase-to-neutral, per EN/IEC 60947-2. The service breaking capacity Ics is 75 % of those values (7.5 kA at 240 V, 2.25 kA at 415 V).

How do I get current pricing and availability for MGN60865?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time.

What compliance documentation does this brand provide for MGN60865?

The MCB is certified to EN/IEC 60947-2. It carries IP20 protection and is rated for pollution degree 3. For specific RoHS/REACH/UL declarations, request the manufacturer's compliance pack with your RFQ.

MPN
MGN60865