MGN60867 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60N
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60867 — Electrical & Protection
ParameterValue
Rated current (In)10 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60867 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60867 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60867 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

MGN60867 — C60N 1P C-curve 10 A MCB

The MGN60867 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, configured as a single-pole unit with a C-curve trip characteristic and a 10 A rated current at 50 °C per EN/IEC 60947-2. Rated breaking capacity is 10 kA Icu at 240 V AC phase-to-neutral, with a corresponding service breaking capacity (Ics) of 7.5 kA at the same voltage — 75 % of the ultimate rating, which is typical for a distribution-grade MCB and means it can safely clear faults up to that level without needing replacement after a single interruption. Pollution degree 3 per EN/IEC 60947-2 suits it for industrial panels where conductive dust or humidity is present.

Mounts fixed on 35 mm DIN rail. The IP20 finger-safe front is standard for enclosed distribution boards. Rated operational voltage is 240 V AC phase-to-neutral. The 1P configuration protects a single pole; earth-leakage protection requires a separate add-on block. A contact position indicator and ON/OFF local signalling are built in. The C60N is category A (no intentional short-time delay), so it coordinates as a standard downstream device in a selective scheme.

Frequently asked questions

What is the breaking capacity of MGN60867?

The MGN60867 has a rated ultimate breaking capacity (Icu) of 10 kA at 240 V AC phase-to-neutral, and a service breaking capacity (Ics) of 7.5 kA at the same voltage, both per EN/IEC 60947-2.

What is the rated current and curve of MGN60867?

It is rated 10 A at 50 °C with a C-curve trip characteristic (magnetic trip at 8.5 x In ±20 %).

What DIN rail width does MGN60867 occupy?

It occupies 2 x 9 mm pitches, which is 18 mm wide, on a standard 35 mm symmetrical DIN rail.

Where can I buy MGN60867?

The MGN60867 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
MGN60867