Schneider Electric MGN60875

MGN60875 C60N Miniature Circuit-Breaker, 1 A, C Curve, 2P, 2

MPN MGN60875
Obsolete

Schneider Electric Multi9 C60N, miniature circuit-breaker, 1 A, C curve, 2 poles, 20 kA Icu at 240 V AC, 73 mm depth, 36 mm width, 81 mm height.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60875 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

MGN60875 additional specifications
ParameterValue
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60875 is a 2-pole C60N miniature circuit-breaker from Schneider Electric's Multi9 range, rated 1 A at 50 °C with a C trip curve. The C curve (magnetic trip at 8.5 x In ±20 %) means it handles moderate inrush — typical for small motor or lighting loads — without nuisance tripping on startup, while still clearing a hard fault fast. Rated operational voltage goes up to 440 V AC, but the breaking capacity derates: 10 kA at 415 V, 6 kA at 440 V. That derating curve is the spec to check when you're coordinating with an upstream breaker in a 400 V panel. It's a thermal-magnetic trip unit, Category A (no intentional short-time delay), so it's a standard distribution MCB — not a selective breaker. The 2-pole version protects both legs of a single-phase circuit or one leg of a DC circuit (the network type is listed as DC,).