Skip to main content
Schneider Electric MGN60878

MGN60878 C60N MCB, 2P C-curve 4 A, 20 kA breaking capacity

MPN MGN60878
Obsolete

Schneider Electric C60N Multi9 miniature circuit-breaker, 2-pole, C-curve, 4 A, 20 kA Icu at 240 V AC, thermal-magnetic, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60878 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60878 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60878 is a Schneider Electric C60N miniature circuit-breaker from the Multi9 range — a 2-pole, C-curve unit rated 4 A at 50 °C per EN/IEC 60947-2. The C-curve magnetic trip at 8.5 x In (±20%) handles motor inrush and transformer energization without nuisance tripping, but still clears fast on a hard short.

The 20 kA Icu at 240 V AC drops to 10 kA at 415 V and 6 kA at 440 V — that's the standard derating for higher system voltages. For a 240 V delta or line-to-line circuit, that's enough headroom for most commercial panels. At 415/440 V, the 6–10 kA range still covers typical industrial distribution, but check your available fault current before committing.

IP20 rated, so it's for enclosed panels only — no washdown exposure. The toggle gives local ON/OFF indication, and the contact position indicator confirms isolation status per EN/IEC 60947-2.

MPN
MGN60878