MGN60879 C60N Miniature Circuit Breaker, 6 A, C-Curve, 2-Pol

MPN MGN60879
Obsolete

Schneider Electric Multi9 C60N, MGN60879, miniature circuit breaker, 6 A, C-curve, 2-pole, 20 kA Icu at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60879 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60879 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric MGN60879 is a C60N miniature circuit breaker from the Multi9 range, rated 6 A at 50 °C with a C-curve trip characteristic (magnetic trip at 8.5 x In +/- 20 %). It's a 2-pole unit, Category A per EN/IEC 60947-2, meaning it's not intended for selectivity under short-circuit conditions — it clears faults fast, which is what you want in a distribution sub-feed or a final branch circuit where you don't need cascaded coordination. The C-curve holds through mild inrush and trips on moderate overloads. Magnetic trip at 8.5 x In +/- 20 %.

This breaker carries a 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V, all per EN/IEC 60947-2. The Ics is 75 % of those figures.

Snaps onto 35 mm symmetrical DIN rail, fixed mounting. Width is 36 mm, which is 4 module pitches at 9 mm each. Depth is 73 mm, height 81 mm — standard Multi9 footprint, so it fits alongside other C60 breakers, RCCBs, and auxiliaries on the same rail without spacing issues. Wire stripping length is 14 mm. The breaker is compatible with comb busbars on top or bottom, which speeds up panel wiring on multi-pole distribution boards.