Skip to main content
Schneider Electric MGN60880

MGN60880 C60N MCB, 2P C-Curve 10 A, 20 kA, Multi9

MPN MGN60880
Obsolete

Schneider Electric C60N Multi9 miniature circuit breaker, MGN60880, 2-pole, C-curve, 10 A rated current, 20 kA breaking capacity at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60880 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60880 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60880 is a C60N miniature circuit breaker from the Multi9 range, 2-pole, C-curve, rated 10 A at 50 °C per EN/IEC 60947-2. The C-curve magnetic trip is 8.5 x In ±20 %, meaning it holds through moderate inrush (lighting, small transformers) but trips fast on hard shorts. Breaking capacity is 20 kA Icu at 240 V AC phase-to-phase, 10 kA at 415 V, and 6 kA at 440 V — the 20 kA figure is the one that governs most panelboard fault-current ratings; the 415 V and 440 V numbers matter only if the line-to-line voltage actually sits at those levels. The 2 protected poles mean both poles have thermal-magnetic trip elements; it isolates both line and neutral in single-phase DC or two legs of a DC system.

Snaps onto 35 mm symmetrical DIN rail, fixed mounting mode. IP20 finger-safe terminals, tunnel type accepting 1…25 mm² rigid or flexible (with or without ferrule). Tightening torque 2 N·m on the power circuit; strip length 14 mm. Comb busbar and distribution block compatible top or bottom, which simplifies daisy-chaining in multi-pole panels.

Ambient operating range -30…70 °C, storage -40…80 °C. Electrical durability 10,000 cycles, mechanical 20,000 cycles. Earth-leakage protection via separate block (not integral).

MPN
MGN60880