Skip to main content
Schneider Electric MGN61839

MGN61839 Multi9 C60H-DC MCB, 1P, 50 A, Curve C, DC

MPN MGN61839
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit-breaker, 1 pole, 50 A rated current, curve C, DC network, clip-on DIN rail, grey.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61839 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 110 V DC 220 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 110 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220 V DC conforming to EN/IEC 60947-2 6 kA Icu at 250 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61839 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit-breaker for distribution panels

The MGN61839 is a Schneider Electric Multi9 C60H-DC miniature circuit-breaker, single-pole, rated 50 A at 50 °C per EN/IEC 60947-2. The thermal-magnetic trip unit with curve C (magnetic tripping at 8.5 x In +/- 20 % DC) provides overcurrent and short-circuit protection for DC distribution circuits. Breaking capacity is 20 kA Icu at 110 V DC, 10 kA at 220 V DC, and 6 kA at 250 V DC — all conforming to EN/IEC 60947-2. This means it can safely interrupt high-energy DC faults up to those levels, essential for battery banks, solar arrays, or DC bus distribution where arc extinction is harder than in AC circuits. The unit is tropicalised (class 2 per IEC 60068-2) for humid conditions up to 95 % RH at 55 °C.

Strip length is 14 mm. For dual or triple conductors, refer to the terminal capacity table: two cables up to 16 mm² rigid, three cables at 4 mm² flexible stranded. IP20 finger-safe terminals; IP40 in modular enclosure.

MPN
MGN61839