Skip to main content
Schneider Electric MGN61847 — 2-Pole MCB (DIN Rail)

MGN61847 Multi9 C60H-DC MCB, 2P, 8 A, C Curve, 20 kA DC

MPNMGN61847
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, MGN61847, 2-pole, 8 A rated current, C curve, breaking capacity 20 kA Icu at 250 V DC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61847 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61847 — Electrical
ParameterValue
Rated current [In]8 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61847 — Protection
ParameterValue
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61847 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61847 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61847 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit breaker for distribution panels

The MGN61847 is a 2-pole DC miniature circuit breaker from the Multi9 C60H-DC series, rated 8 A at 50 °C with a C curve (magnetic trip at 8.5 x In ±20 % DC). Its breaking capacity reaches 20 kA Icu at 220/250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC — covering the common DC bus voltages in industrial control panels and telecom distribution. Clip-on mounting to DIN rail (36 mm wide, 4 x 9 mm pitches) and tunnel terminals accepting up to 25 mm² rigid stranded make it a direct swap in existing Multi9 distribution boards. The toggle switch provides local ON/OFF indication and is padlockable for lockout/tagout.

Breaking capacity and selectivity in DC circuits

The 20 kA Icu at 250 V DC is the headline figure — enough to clear faults on most 250 V DC bus systems without cascading upstream.

Integration into DC distribution panels

The 36 mm width (2-pole) fits Multi9 comb busbars and accessory footprints. Tunnel terminals accept one or two conductors per pole — up to 25 mm² rigid stranded, or 16 mm² flexible with ferrule. Tightening torque 2.5 N·m; strip length 14 mm. Pollution degree 3 (industrial environment) and tropicalisation class 2 per IEC 60068-2 cover high-humidity installations (95 % RH at 55 °C).

Frequently asked questions

Where can I buy MGN61847 and how do I get a price?

The MGN61847 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is MGN61847's breaking capacity at 250 V DC?

The MGN61847 has a breaking capacity of 20 kA Icu at 250 V DC per EN/IEC 60947-2.

What compliance standards does MGN61847 meet?

The MGN61847 is designed to EN/IEC 60947-2, with pollution degree 3, tropicalisation class 2, and IP20 (IP40 in modular enclosure) protection.

MPN