Schneider Electric MGN61850 Multi9 C60H-DC MCB, 16 A, 2P, Cu

MPN MGN61850
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61850, miniature circuit breaker, 16 A, 2P, curve C, DC rated, breaking capacity 20 kA at 250 V DC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61850 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61850 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated MCB for distribution panels

The Schneider Electric MGN61850 is a Multi9 C60H-DC miniature circuit breaker rated 16 A at 50 °C, with 2 protected poles and a C trip curve. It's built for DC networks — the magnetic trip threshold is 8.5 x In ±20% DC, and the breaking capacity hits 20 kA Icu at 250 V DC per EN/IEC 60947-2. That's the rating that matters for a 250 VDC bus; at 440 V DC it still interrupts 10 kA, and at 500 V DC it holds 6 kA. Pollution degree 3 and tropicalisation class 2 mean it handles humid, dirty panel environments without derating.

The 16 A rated current (In) at 50 °C is the continuous load it carries without tripping — spec it for the branch circuit's expected draw, not the breaker's thermal limit. The 2-pole configuration (both poles switched and protected) is standard for ungrounded DC systems where you need full isolation on both legs.

Clip-on DIN rail mounting, 36 mm wide (4 modules). Tunnel terminals accept up to 25 mm² rigid stranded or 16 mm² flexible; strip length 14 mm, torque to 2.5 N·m. The toggle gives local ON/OFF indication with a padlockable handle for lockout/tagout.