Skip to main content
Schneider Electric MGN61851

MGN61851 Multi9 C60H-DC 20A C-Curve 2P DC MCB, 20 kA at 250

MPN MGN61851
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, 2-pole, 20 A, C-curve, DC rated, breaking capacity 20 kA at 250 V DC, clip-on DIN rail mount, grey.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61851 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61851 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The MGN61851 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker — a 2-pole, 20 A, C-curve unit built for DC networks.

Breaking capacity and voltage ratings

The DC breaking capacity is specified at four voltage points: 20 kA Icu at 220 V DC, 20 kA at 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC. That means in a 250 V DC bus (common in telecom or solar combiner boxes), the breaker clears a 20 kA fault without external current limiting. At the higher 500 V DC level (typical in some battery banks), the interrupting capacity drops to 6 kA — still adequate for most series-string faults, but verify your available fault current against the 6 kA limit.

DIN rail integration and terminal sizing

The IP20 finger-safe front face and IP40 modular enclosure rating let it sit in a standard distribution board without additional shrouding. Padlockable toggle for lockout/tagout compliance.

MPN
MGN61851