Skip to main content
Schneider Electric MGN61876 — 2-Pole MCB (DIN Rail)

MGN61876 Multi9 C60H-DC MCB, 2A Curve K, 2P DC, 20 kA

MPNMGN61876
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit-breaker, MGN61876, 2 A rated current, curve K, 2 poles DC, 20 kA breaking capacity at 220 V DC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61876 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61876 — Electrical
ParameterValue
Rated current [In]2 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61876 — Protection
ParameterValue
Tripping curve codeK
Magnetic tripping limit12 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61876 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61876 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61876 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC miniature circuit-breaker, 2 A curve K, 2 poles

The Schneider Electric MGN61876 is a Multi9 C60H-DC miniature circuit-breaker rated 2 A with a K trip curve, designed for DC networks. It protects 2 poles with a thermal-magnetic trip unit, magnetic tripping at 12 x In ±20% DC. Breaking capacity reaches 20 kA Icu at 220 V DC, 20 kA at 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC per EN/IEC 60947-2. The 2 A rating at 50°C means it handles continuous DC loads up to that current — sized for control circuits, signal supplies, or small DC distribution branches where a K curve's wider magnetic threshold avoids nuisance trips from inrush. Clip-on mounting to DIN rail, 36 mm width (4 x 9 mm pitches), 81 mm height, 73 mm depth. IP20 finger-safe front; IP40 inside the modular enclosure. Tightening torque 2.5 N·m. Padlockable for lockout/tagout. ON/OFF indication visible on the toggle.

DC selectivity and coordination

For a 2 A breaker, that's 24 A instantaneous trip. This suits loads with moderate inrush (DC motors, solenoids, capacitive inputs) where a B curve would nuisance-trip but a Z curve would be too slow. Rated insulation voltage 500 V DC; operational voltages include 220 V, 250 V, 440 V, and 500 V DC. Category A per EN/IEC 60947-2 — not intended for selectivity under short-circuit with downstream breakers, but suitable for standalone branch protection.

Panel integration

Snap onto DIN rail — 36 mm width occupies 4 module positions in a standard enclosure. Tunnel terminals with 14 mm strip length; wire range 1–25 mm² rigid stranded. Dual and triple-wire entries simplify daisy-chaining DC buses. Padlockable toggle for lockout compliance. IP20 front allows panel-mount without additional finger-duct covers.

Frequently asked questions

What is the breaking capacity of MGN61876 at 220 V DC?

20 kA Icu at 220 V DC per EN/IEC 60947-2. Also rated 20 kA at 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC.

What does curve K mean on this DC breaker?

Magnetic trip at 12 x In ±20% DC — for a 2 A breaker, instantaneous trip above approximately 24 A. Suited for DC loads with moderate inrush where a B curve would nuisance-trip.

What compliance standards does MGN61876 meet?

EN/IEC 60947-2 for miniature circuit-breakers, pollution degree 3, tropicalisation class 2 per IEC 60068-2. Suitable for isolation per the standard.

Where can I buy MGN61876 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN