MGN61880 Multi9 C60H-DC MCB, 6 A, 2P, Curve K, DC

MPN MGN61880
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61880, miniature circuit-breaker, 6 A, 2 poles, curve K, 20 kA Icu at 220 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61880 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61880 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit-breaker for distribution panels

The Schneider Electric MGN61880 is a Multi9 C60H-DC miniature circuit-breaker rated 6 A at 50 °C, with 2 poles and a K-curve trip characteristic. It is designed for DC network protection in distribution applications, with a breaking capacity of 20 kA Icu at 220 V DC and 10 kA Icu at 440 V DC per EN/IEC 60947-2. The thermal-magnetic trip unit has a magnetic tripping limit of 12 x In ±20 % DC, meaning it will trip instantaneously on short-circuit currents above roughly 72 A — suitable for protecting DC loads like drives, rectifiers, and battery banks where the K-curve provides a wider margin against nuisance tripping from inrush than a B- or C-curve would.

The 73 mm depth and 81 mm height fit standard modular enclosure cutouts. Tunnel-type terminals accept up to 25 mm² rigid stranded or 16 mm² flexible wire; strip length 14 mm, tighten to 2.5 N.m. IP20 finger-safe front, IP40 within the modular enclosure. Padlockable toggle for lockout/tagout.

Rated insulation voltage 500 V DC and operational voltages of 220 / 250 / 440 / 500 V DC cover common DC bus and battery string voltages. The 2-pole configuration protects both conductors in a DC circuit. Suitable for isolation — verified by the contact position indicator and ON/OFF local signalling. Tropicalisation class 2 per IEC 60068-2 confirms it withstands damp heat cycling. Mechanical durability of 20,000 cycles and electrical durability of 3,000 cycles at L/R = 2 ms give a realistic service life for a panel breaker.