Skip to main content
Schneider Electric MGN61882

MGN61882 Multi9 C60H-DC MCB, 10 A, 2P, K-curve, 20 kA DC

MPN MGN61882
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61882, miniature circuit breaker, 2-pole, 10 A, K-curve, 20 kA breaking capacity at 250 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61882 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61882 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The MGN61882 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker, 2-pole, rated 10 A at 50 °C per EN/IEC 60947-2, with a K-curve trip characteristic. It is built for DC networks — 220 V, 250 V, 440 V, or 500 V DC — and delivers a breaking capacity of 20 kA Icu at 250 V DC. The thermal-magnetic trip unit has a magnetic tripping limit of 12 x In (±20 % DC), so it handles high inrush loads like DC motor drives or solenoids without nuisance trips. The tunnel terminals accept up to 25 mm² rigid stranded (AWG 4) or 16 mm² flexible; torque to 2.5 N·m. IP20 finger-safe front, IP40 inside the modular enclosure. Padlockable toggle provides ON/OFF indication and contact position indication for safe isolation.

Mechanical durability is rated at 20,000 cycles, electrical durability at 3,000 cycles (L/R = 2 ms). Pollution degree 3 per EN 60947-2, tropicalisation class 2 per IEC 60068-2. Relative humidity tolerance: 95 % at 55 °C. The breaker is suitable for isolation — it provides a visible contact gap when toggled OFF.

MPN
MGN61882