Schneider Electric MGN61882 — 2-Pole MCB (DIN Rail)

MGN61882 Multi9 C60H-DC MCB, 10 A, 2P, K-curve, 20 kA DC

MPNMGN61882
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61882, miniature circuit breaker, 2-pole, 10 A, K-curve, 20 kA breaking capacity at 250 V DC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61882 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61882 — Electrical
ParameterValue
Rated current [In]10 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61882 — Protection
ParameterValue
Tripping curve codeK
Magnetic tripping limit12 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61882 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61882 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61882 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

The MGN61882 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker, 2-pole, rated 10 A at 50 °C per EN/IEC 60947-2, with a K-curve trip characteristic. It is built for DC networks — 220 V, 250 V, 440 V, or 500 V DC — and delivers a breaking capacity of 20 kA Icu at 250 V DC. The thermal-magnetic trip unit has a magnetic tripping limit of 12 x In (±20 % DC), so it handles high inrush loads like DC motor drives or solenoids without nuisance trips. The tunnel terminals accept up to 25 mm² rigid stranded (AWG 4) or 16 mm² flexible; torque to 2.5 N·m. IP20 finger-safe front, IP40 inside the modular enclosure. Padlockable toggle provides ON/OFF indication and contact position indication for safe isolation.

Mechanical durability is rated at 20,000 cycles, electrical durability at 3,000 cycles (L/R = 2 ms). Pollution degree 3 per EN 60947-2, tropicalisation class 2 per IEC 60068-2. Relative humidity tolerance: 95 % at 55 °C. The breaker is suitable for isolation — it provides a visible contact gap when toggled OFF.

Frequently asked questions

Where can I buy MGN61882?

The MGN61882 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest alternative to MGN61882 in the Multi9 range?

Within the same Multi9 C60H-DC family, the closest alternative would be a different current rating or pole configuration. No pin-compatible direct alternative is listed — the MGN61882 is the current active order code for a 2-pole, 10 A, K-curve DC breaker.

What compliance documentation does Schneider provide for MGN61882?

The MGN61882 is certified to EN/IEC 60947-2. Further compliance documentation (RoHS, REACH, UL) should be confirmed at the time of order via the RFQ process — the manufacturer's standard declarations apply.

MPN