Schneider Electric MGN61885 Multi9 C60H-DC MCB, 20 A, 2P, K-

MPN MGN61885
Obsolete

Schneider Electric Multi9 C60H-DC, miniature circuit breaker, MGN61885, 2P, 20 A, K-curve, 500 V DC insulation, 20 kA breaking capacity at 250 V DC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61885 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61885 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit breaker for distribution panels

The Schneider Electric MGN61885 is a Multi9 C60H-DC miniature circuit breaker rated 20 A at 50 °C per EN/IEC 60947-2, with a K-curve magnetic trip set at 12 x In ±20 % for DC networks. It is a 2-pole (2P) device, meaning both poles switch and protect the DC circuit — no shared neutral path. The breaking capacity reaches 20 kA Icu at 250 V DC and 10 kA Icu at 440 V DC, so it handles fault currents on common 250 V and 440 V DC bus voltages found in industrial control and telecom distribution. Clip it onto a DIN rail (4 module pitches, 36 mm wide) inside an IP40 modular enclosure or an IP20 panel. The tunnel terminals accept 1…25 mm² rigid stranded or 1…16 mm² flexible, single or dual conductors, with a stripping length of 14 mm and a tightening torque of 2.5 N.m. This covers most panel wiring from control-circuit feeds to small distribution subfeeds.

K-curve trip and DC-only application

The K-curve (12 x In magnetic trip) is chosen for DC loads with moderate inrush — think DC motor drives, solenoid banks, or capacitive loads where a B-curve would nuisance-trip and a Z-curve would be too slow. The thermal-magnetic trip unit provides overload protection via the bimetal strip and short-circuit protection via the solenoid. This is a DC-only breaker (network type DC). The rated operational voltages are 220 V DC, 250 V DC, 440 V DC, and 500 V DC, with an insulation voltage of 500 V DC. Do not apply it on AC circuits — the arc extinction method and magnetic trip calibration are specific to DC.

Environmental and compliance ratings

IP20 finger-safe terminals; IP40 when installed in a modular enclosure.