Schneider Electric MGP0201L2 — 1-Pole MCB (DIN Rail)

MGP0201L2 PowerPacT 4 MCCB, 20A, 1P, 230V, Obsolete

MPNMGP0201L2
Obsolete

Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0201L2, 1-pole, 20 A, 230 V AC, 25 kA Icu/Ics, thermal-magnetic TM-D trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0201L2 — Identification
ParameterValue
Product / component typeCircuit breaker
Poles description1P
Device applicationDistribution
MGP0201L2 — Electrical & Protection
ParameterValue
Rated current (In)20 A at 40 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGP0201L2 — Mounting & Connection
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0201L2 — Approvals
ParameterValue
Conformity standardsBS EN 60947-2
MGP0201L2 — Electrical
ParameterValue
[Ui] rated insulation voltage750 V
[Uimp] rated impulse withstand voltage8 kV

Product details

The MGP0201L2 is a Schneider Electric PowerPacT 4 molded case circuit breaker (MCCB), 1-pole, rated 20 A at 40 °C on a 230 V AC 50/60 Hz system. The toggle control and backplate mounting suit panel-board or enclosure integration, and it's rated for isolation per BS EN 60947-2.

This part is marked obsolete by the manufacturer. No official successor order code is listed in the lifecycle record. Don't assume a drop-in replacement from the same family; the PowerPacT 4 series has been superseded, and a parametric cross-check (poles, current, breaking capacity, voltage, trip curve) is needed before substituting.

Ics equals Icu here, so it can re-close after a fault at full rating. The 750 V rated insulation voltage (Ui) and 8 kV impulse withstand (Uimp) confirm it's built for distribution panels, not just branch circuits. The 1-pole, L2 phase connection means it's a single-pole breaker for a 230 V line-to-neutral or line-to-line circuit — not for a 3-phase main.

Frequently asked questions

What is MGP0201L2's listed standard?

It is certified to BS EN 60947-2, the standard for molded case circuit breakers, and is suitable for isolation per that same standard.

What is the breaking capacity of MGP0201L2?

Both the ultimate (Icu) and service (Ics) short-circuit breaking capacities are 25 kA at 230 V AC 50/60 Hz. Ics equals Icu, so the breaker can be reclosed after clearing a fault at its full rating.

What trip unit does MGP0201L2 use?

It uses a TM-D thermal-magnetic trip unit with LI protection: thermal for overload (L) and magnetic for short-circuit (I). The thermal adjustment is fixed at 20 A.