Schneider Electric MGP0251L2 — 1-Pole MCB (DIN Rail)

Schneider Electric MGP0251L2 PowerPacT 4 MCCB, 1P 25A, Obsol

MPNMGP0251L2
Obsolete

Schneider Electric PowerPacT 4 molded case circuit breaker, 1-pole, 25 A at 40 °C, 230 V AC, 25 kA breaking capacity, TM-D trip unit, BS EN 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0251L2 — Identification
ParameterValue
Product / component typeCircuit breaker
Poles description1P
Device applicationDistribution
MGP0251L2 — Electrical & Protection
ParameterValue
Rated current (In)25 A at 40 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGP0251L2 — Mounting & Connection
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0251L2 — Approvals
ParameterValue
Conformity standardsBS EN 60947-2
MGP0251L2 — Electrical
ParameterValue
[Ui] rated insulation voltage750 V
[Uimp] rated impulse withstand voltage8 kV

Product details

The Schneider Electric MGP0251L2 is a PowerPacT 4 molded case circuit breaker (MCCB) — one pole, rated 25 A at 40 °C, for 230 V AC 50/60 Hz distribution. That LI protection curve is what you expect from a standard distribution breaker — no earth-leakage function built in.

Both Icu (ultimate) and Ics (service) breaking capacity are 25 kA at 230 V AC. The 8 kV impulse withstand (Uimp) and 750 V rated insulation voltage (Ui) give it headroom for transient-heavy environments.

Panel-mounted via backplate, accepts horizontal or vertical orientation. It takes one 35 mm module width. The toggle control is manual — no remote trip or shunt trip option in this variant. Rated for isolation per BS EN 60947-2, so it doubles as a visible-break disconnect in the right circuit.

Durability in the field

Mechanical endurance is 20,000 cycles. Electrical endurance at rated load: 20,000 cycles at 277 V at In/2, and 10,000 cycles at 277 V at full In. That is typical for a molded case breaker in this class — plenty for a distribution panel that sees occasional switching, not a motor-starting duty cycle.

Frequently asked questions

What are the key ratings of the MGP0251L2?

25 A rated current at 40 °C, 230 V AC 50/60 Hz operational voltage, 25 kA Icu/Ics breaking capacity at 230 V AC, 8 kV impulse withstand, 750 V insulation voltage. Thermal-magnetic LI protection via a TM-D trip unit.

What standard does the MGP0251L2 comply with?

It is certified to BS EN 60947-2, the standard for low-voltage switchgear and controlgear — specifically for circuit breakers. It is also suitable for isolation per that same standard.