Schneider Electric MGP0252L1N — 1-Pole MCB (DIN Rail)

Schneider MGP0252L1N PowerPacT 4 MCCB, 25A, 1P+N, Obsolete

MPNMGP0252L1N
Obsolete

Schneider Electric PowerPacT 4, MGP0252L1N, Molded Case Circuit Breaker, 1P+N, 25A at 40°C, 230 V AC, TM-D trip unit, LI protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0252L1N — Identification
ParameterValue
Product / component typeCircuit breaker
Poles description1P + N
Device applicationDistribution
MGP0252L1N — Electrical & Protection
ParameterValue
Rated current (In)25 A at 40 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGP0252L1N — Mounting & Connection
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0252L1N — Approvals
ParameterValue
Conformity standardsBS EN 60947-2
MGP0252L1N — Electrical
ParameterValue
[Ui] rated insulation voltage750 V
[Uimp] rated impulse withstand voltage8 kV

Product details

The Schneider Electric MGP0252L1N is a PowerPacT 4 molded case circuit breaker (MCCB) with a 1P+N pole configuration, rated 25 A at 40 °C for 230 V AC distribution circuits.

Breaking capacity and isolation

That makes it suitable for panelboards where selectivity coordination matters downstream of a larger upstream breaker. The part is certified for isolation per BS EN 60947-2, meaning you can safely use it as a disconnecting means with visible gap confirmation. Rated insulation voltage (Ui) of 750 V and impulse withstand (Uimp) of 8 kV give headroom for transient-rich environments like industrial motor control centers. The toggle control type means manual on/off switching — no remote trip or shunt-trip accessory built in.

Lifecycle status — obsolete, sourced on request

The MGP0252L1N is marked Obsolete. No successor order code is in the evidence.

Frequently asked questions

What are the key ratings of MGP0252L1N?

25 A rated current at 40 °C, 230 V AC operational voltage, 25 kA Icu/Ics at 415 V AC, 1P+N poles, TM-D thermal-magnetic trip unit with LI protection, and BS EN 60947-2 certification for isolation.

What standards does MGP0252L1N comply with?

It complies with BS EN 60947-2, the standard for low-voltage switchgear and controlgear — specifically for circuit breakers. It is also certified for isolation per that same standard.

MPN