Schneider Electric MGP0252L2N — 1-Pole MCB (DIN Rail)

Schneider Electric MGP0252L2N PowerPacT 4 MCCB, 25 A, 1P+N,

MPNMGP0252L2N
Obsolete

Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0252L2N, 1P+N, 25 A at 40 °C, 230 V AC, 25 kA Icu at 415 V AC, TM-D trip unit, LI protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0252L2N — Identification
ParameterValue
Product / component typeCircuit breaker
Poles description1P + N
Device applicationDistribution
MGP0252L2N — Electrical & Protection
ParameterValue
Rated current (In)25 A at 40 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGP0252L2N — Mounting & Connection
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0252L2N — Approvals
ParameterValue
Conformity standardsBS EN 60947-2
MGP0252L2N — Electrical
ParameterValue
[Ui] rated insulation voltage750 V
[Uimp] rated impulse withstand voltage8 kV

Product details

The Schneider Electric MGP0252L2N is a PowerPacT 4 molded case circuit breaker (MCCB) rated 25 A at 40 °C, 1P+N (L2-N), 230 V AC 50/60 Hz, with a TM-D thermal-magnetic trip unit providing LI protection (overload and short-circuit). It carries a 25 kA Icu and Ics at 415 V AC, Category A utilization, and is suitable for isolation per BS EN 60947-2. The unit is panel-mounted, fits a 2-module (35 mm) footprint, and can be mounted horizontally or vertically.

The 8 kV impulse withstand voltage (Uimp) means it handles transient surges common in industrial panels without flashover. The 750 V rated insulation voltage (Ui) gives headroom for the internal isolation path. The 20000-cycle mechanical durability and 20000-cycle electrical durability at rated current give a sense of the service life under normal switching — though in distribution duty, it's mostly sitting closed.

This is a distribution-circuit breaker — it protects branch circuits in panelboards, subpanels, or directly on a backplate in a control cabinet. The 1P+N configuration (switching the line, monitoring neutral) is typical for single-phase loads in commercial or light industrial distribution. The panel-mount form factor and 2-module width (35 mm) mean it fits standard DIN-rail or backplate layouts, though it's not a snap-on DIN rail breaker — it's bolted to the backplate.

Frequently asked questions

Where can I buy the MGP0252L2N?

We source the MGP0252L2N to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response.

What standards does the MGP0252L2N comply with?

The MGP0252L2N is listed to BS EN 60947-2, the standard for low-voltage switchgear and controlgear — specifically for circuit breakers. It is also suitable for isolation per that standard.

What is the control type on the MGP0252L2N?

The control type is Toggle — a manual toggle handle on the front of the breaker for on/off operation.