Schneider Electric MGP0252L31 — 2-Pole MCB (DIN Rail)

MGP0252L31 PowerPacT 4 MCCB, 25A, 25kA, 415V, Obsolete

MPNMGP0252L31
Obsolete

Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0252L31, 2-pole, 25A, 25kA Icu at 415V AC, thermal-magnetic TM-D trip unit, BS EN 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0252L31 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP0252L31 — Electrical
ParameterValue
Rated current [In]25 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP0252L31 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP0252L31 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0252L31 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The Schneider Electric MGP0252L31 is a PowerPacT 4 molded case circuit breaker (MCCB), 2-pole, rated 25 A at 40 °C with a TM-D thermal-magnetic trip unit providing LI protection — thermal overload (L) and magnetic short-circuit (I). It is rated for 415 V AC 50/60 Hz operational voltage and delivers 25 kA Icu / Ics ultimate and service short-circuit breaking capacity at that voltage, meeting Category A utilisation per BS EN 60947-2.

This part is officially obsolete per the manufacturer's lifecycle status.

The 25 A thermal-magnetic trip unit is fixed — no adjustment range beyond the 25 A setting — so it must match the continuous load current of the protected circuit exactly. The 2-pole configuration (L3- phase connection) makes it a single-phase or two-pole distribution breaker, not a three-phase device. Rated insulation voltage is 750 V and impulse withstand is 8 kV, giving headroom for 415 V AC systems. Mechanical durability is 20,000 cycles; electrical durability is 20,000 cycles at rated current and 10,000 at 2× In — figures that matter for frequent switching applications like lighting or motor control centres.

Deployment context

Panel-mounted via backplate, with horizontal or vertical orientation allowed — typical for distribution boards where the breaker is bolted to a mounting plate rather than snapped onto DIN rail. Occupies 2 modules of 35 mm width, so panel layout can be planned accordingly.

Frequently asked questions

Where can I buy MGP0252L31?

The MGP0252L31 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

What standards does MGP0252L31 comply with?

The MGP0252L31 complies with BS EN 60947-2, the standard for low-voltage switchgear and controlgear — circuit-breakers.

What is the breaking capacity of MGP0252L31?

The MGP0252L31 has a rated ultimate short-circuit breaking capacity (Icu) of 25 kA and a rated service breaking capacity (Ics) of 25 kA at 415 V AC 50/60 Hz.

MPN
MGP0252L31