Schneider Electric MGP0302L23 — 2-Pole MCB (DIN Rail)

Schneider Electric MGP0302L23 PowerPacT 4 MCCB, 30A 2P 415V

MPNMGP0302L23
Obsolete

Schneider Electric PowerPacT 4, MGP0302L23, Molded Case Circuit Breaker, 2P, 30A, 415 V AC, 25 kA Icu/Ics, TM-D trip unit, LI protection, panel-mounted.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0302L23 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP0302L23 — Electrical
ParameterValue
Rated current [In]30 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP0302L23 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP0302L23 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0302L23 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

Breaking capacity is 25 kA Icu and 25 kA Ics at 415 V AC 50/60 Hz — both ratings are equal, meaning the breaker can clear a fault at its full interrupting rating and be immediately reclosed without derating. This simplifies coordination studies in a 415 V distribution board. Rated operational voltage is 415 V AC, insulation voltage 750 V, and impulse withstand 8 kV — figures consistent with a Category A utilization breaker for distribution duty per BS EN 60947-2. The 2-pole configuration connects L2-L3 phases only, so it is not a full 3-phase disconnect. Panel-mounted on a backplate, accepts horizontal or vertical orientation.

Deployment Context

Intended for distribution applications — typically a branch circuit breaker in a 415 V AC panel feeding a single-phase or two-phase load (L2-L3). The toggle control type gives a visible on/off position for manual operation and lockout. Rated for 20,000 electrical cycles at rated current and 20,000 mechanical cycles — sufficient for a distribution breaker that sees infrequent switching, not a motor-starting duty cycle.