Schneider Electric MGP0302L31 — 2-Pole MCB (DIN Rail)

MGP0302L31 PowerPacT 4 MCCB, 30 A, 25 kA, Obsolete

MPNMGP0302L31
Obsolete

Schneider Electric PowerPacT 4 series, MGP0302L31, 2-pole molded case circuit breaker, 30 A thermal-magnetic TM-D trip unit, 25 kA Icu/Ics at 415 V AC, BS EN 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0302L31 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP0302L31 — Electrical
ParameterValue
Rated current [In]30 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP0302L31 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP0302L31 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0302L31 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The MGP0302L31 is a 2-pole molded case circuit breaker from the Schneider Electric PowerPacT 4 range, fitted with a TM-D thermal-magnetic trip unit rated at 30 A at 40 °C. It is designed for distribution duty in panel-mounted backplate installations, with horizontal or vertical mounting flexibility. The control interface is a toggle mechanism. Rated operational voltage is 415 V AC at 50/60 Hz, with an insulation voltage of 750 V and impulse withstand of 8 kV. This places it in utilisation category A, meaning it is not intended for current-limiting applications requiring category B selectivity. The LI protection profile covers thermal overload (L) via a bimetal element and magnetic short-circuit (I) via a solenoid, both fixed at the 30 A rating with no adjustable thermal band.

Schneider Electric has classified the MGP0302L31 as Obsolete. No direct official successor order code is listed in the available records. The mechanical endurance is rated at 20,000 cycles, with electrical durability of 20,000 cycles at rated current and 10,000 cycles at 2× In at 277 V. These figures reflect the expected service life under nominal conditions; the breaker is not designed for frequent switching duty.

The 2-pole configuration with L3- phase connection means it switches both poles simultaneously, suited for single-phase or two-phase loads. The 2-module width (35 mm per module) on a backplate mount is a standard footprint for panel builders. No earth-leakage protection is integrated; if ground-fault detection is needed, an external RCD or RCBO must be added downstream.

Frequently asked questions

Where can I buy MGP0302L31?

We source the MGP0302L31 to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What standards does the MGP0302L31 comply with?

The breaker is certified to BS EN 60947-2 and is suitable for isolation per that standard. It carries no listed UL, CSA, or CE markings in the available record.

What is the breaking capacity of MGP0302L31?

Both Icu and Ics are 25 kA at 415 V AC 50/60 Hz. The Ics equals the Icu, meaning the breaker can be reclosed after clearing a fault at its full rating without derating.