Schneider Electric MGP0402L31 — 2-Pole MCB (DIN Rail)

Schneider Electric MGP0402L31 PowerPacT 4 MCCB, 40A, 2P, 25k

MPNMGP0402L31
Obsolete

Schneider Electric PowerPacT 4 series, MGP0402L31 molded case circuit breaker, 2-pole, 40 A, 415 V AC, 25 kA Icu, thermal-magnetic TM-D trip unit, toggle control.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0402L31 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP0402L31 — Electrical
ParameterValue
Rated current [In]40 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP0402L31 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP0402L31 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0402L31 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The Schneider Electric MGP0402L31 is a PowerPacT 4 molded case circuit breaker (MCCB) with 2 poles, rated 40 A at 40 °C, and a thermal-magnetic TM-D trip unit providing LI protection — thermal overload (L) and magnetic short-circuit (I). Rated operational voltage is 415 V AC at 50/60 Hz, with an insulation voltage of 750 V and impulse withstand of 8 kV. Mechanical durability is rated at 20,000 cycles, with electrical durability of 20,000 cycles at 277 V In/2 and 10,000 cycles at 277 V In.

If a direct replacement is needed, a parametric cross-reference within the PowerPacT 4 family or a current-series equivalent (such as the PowerPacT H or J frame) should be evaluated based on the same 40 A, 2-pole, 25 kA Icu at 415 V AC specification. The thermal-magnetic TM-D trip and LI protection profile are the key fit criteria.

Deployment context

Panel-mounted on a backplate, this MCCB occupies a 2-module (35 mm per module) footprint and can be mounted horizontally or vertically. It connects phase-to-phase L3-. The toggle control provides manual on/off and trip indication — no rotary handle or motor operator is integrated.

Frequently asked questions

What is the breaking capacity of MGP0402L31?

The ultimate short-circuit breaking capacity (Icu) is 25 kA at 415 V AC 50/60 Hz, and the service breaking capacity (Ics) is also 25 kA at the same voltage — meaning it can clear a fault at full rated current without derating for repetitive duty.

What standards does MGP0402L31 comply with?

The MGP0402L31 complies with BS EN 60947-2, the standard for low-voltage switchgear and controlgear — specifically for circuit breakers. It is also suitable for isolation per that standard.

Where can I buy MGP0402L31?

The MGP0402L31 is obsolete and not available through the factory channel. It is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.