Skip to main content
Schneider Electric MGP0632L23 — 2-Pole MCB (DIN Rail)

MGP0632L23 PowerPacT 4 MCCB, 63 A, 25 kA, Obsolete

MPNMGP0632L23
Obsolete

Schneider Electric PowerPacT 4 molded case circuit breaker, 2-pole, 63 A, 25 kA Icu at 415 V AC, thermal-magnetic TM-D trip unit, BS EN 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0632L23 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP0632L23 — Electrical
ParameterValue
Rated current [In]63 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP0632L23 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP0632L23 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0632L23 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The MGP0632L23 is a 2-pole PowerPacT 4 molded case circuit breaker from Schneider Electric, rated 63 A at 40 °C with a thermal-magnetic TM-D trip unit providing LI protection (overload and short-circuit). Breaking capacity is 25 kA Icu and 25 kA Ics at 415 V AC 50/60 Hz — the Ics equals Icu, meaning the breaker can be reclosed after a fault at full rated short-circuit without derating, a useful feature for service continuity in panel designs. Rated insulation voltage is 750 V, impulse withstand voltage 8 kV. The unit is panel-mounted, backplate-supported, and can be installed horizontally or vertically. Phase connection is L2-L3.

The breaker occupies a 2-module (35 mm per module) footprint on a backplate. Panel-mounting with horizontal or vertical orientation gives flexibility in crowded enclosures. The toggle control is manual; no earth-leakage protection is integrated — external RCD required if needed. Mechanical durability is rated at 20,000 cycles; electrical durability is 20,000 cycles at rated current (277 V In/2) and 10,000 cycles at full 277 V In. These figures are typical for a distribution-grade MCCB and support moderate switching duty in panel feeder applications.

Frequently asked questions

Where can I buy MGP0632L23 and how do I get a price?

The MGP0632L23 can be sourced to order against an RFQ through independent distribution. Current pricing and availability are confirmed at the time of quotation — submit an RFQ for a firm quote.

What is MGP0632L23's breaking capacity and voltage rating?

The MGP0632L23 has a rated ultimate short-circuit breaking capacity (Icu) of 25 kA and a rated service breaking capacity (Ics) of 25 kA at 415 V AC 50/60 Hz. Rated operational voltage is 415 V AC, insulation voltage 750 V, impulse withstand 8 kV.

What standards does MGP0632L23 comply with?

The MGP0632L23 complies with BS EN 60947-2, the standard for low-voltage switchgear and controlgear — circuit-breakers. It is also suitable for isolation per that standard.

MPN
MGP0632L23