Schneider Electric MGP0802L12 — 2-Pole MCB (DIN Rail)

Schneider Electric MGP0802L12 PowerPacT 4 MCCB, 80 A, 25 kA

MPNMGP0802L12
Obsolete

Schneider Electric PowerPacT 4 series, MGP0802L12 molded case circuit breaker, 2-pole, 80 A, 415 V AC, 25 kA Icu, thermal-magnetic TM-D trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0802L12 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP0802L12 — Electrical
ParameterValue
Rated current [In]80 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP0802L12 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP0802L12 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP0802L12 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The MGP0802L12 is a 2-pole PowerPacT 4 molded case circuit breaker from Schneider Electric, rated 80 A at 40 °C with a 25 kA Icu/Ics breaking capacity at 415 V AC. It uses a thermal-magnetic TM-D trip unit for LI protection — thermal for overload, magnetic for short-circuit. This is a Category A breaker (no intentional short-time delay), suited for distribution panels where coordination with downstream devices is handled by the instantaneous trip.

The Ics is also 25 kA, meaning it can clear that same fault level and still be serviceable afterward. That's a high-uptime spec for a distribution panel where nuisance trips on a fault mean you don't want to replace the breaker. The 415 V operational voltage covers standard 400 V three-phase systems in Europe and Asia. The 750 V insulation voltage and 8 kV impulse withstand give it margin for transient surges on industrial lines.

Panel-mounted on a backplate, with horizontal or vertical orientation allowed. It occupies 2 modules of 35 mm width. The toggle control is manual; no motor operator or shunt trip built in. Phase connection is -L2, so it's a line-to-line 2-pole breaker, not a 2-pole common-trip for a single-phase line-neutral circuit. Suitable for isolation per BS EN 60947-2 — the toggle provides visible indication of contact position. Mechanical durability is 20,000 cycles; electrical durability is 20,000 cycles at rated current and 10,000 at 2x In.

Frequently asked questions

What standards does the MGP0802L12 comply with?

It complies with BS EN 60947-2, the standard for low-voltage switchgear and controlgear — specifically for molded case circuit breakers. It is also suitable for isolation per that same standard.

What is the breaking capacity of MGP0802L12?

Both the ultimate (Icu) and service (Ics) short-circuit breaking capacities are 25 kA at 415 V AC 50/60 Hz. That means it can clear a 25 kA fault and remain usable afterward.

Where can I buy the MGP0802L12?

This obsolete part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a current status.