Skip to main content
Schneider Electric MGP1002L23 — 2-Pole MCB (DIN Rail)

Schneider MGP1002L23 PowerPacT 4 MCCB, 2P, 100A, 25kA, BS EN

MPNMGP1002L23
Obsolete

Schneider Electric PowerPacT 4 molded case circuit breaker, 2-pole (L2+L3), 100 A, 25 kA Icu at 415 V AC, thermal-magnetic trip unit TM-D, BS EN 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP1002L23 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP1002L23 — Electrical
ParameterValue
Rated current [In]100 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP1002L23 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP1002L23 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP1002L23 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The Schneider Electric MGP1002L23 is a PowerPacT 4 molded case circuit breaker, 2-pole (L2+L3), rated 100 A at 40 °C with a thermal-magnetic TM-D trip unit providing LI protection (thermal overload and magnetic short-circuit). It is certified to BS EN 60947-2 and carries a 25 kA Icu / Ics at 415 V AC 50/60 Hz, making it suitable for distribution panels requiring a Category A breaker with isolation capability.

The Ics is the same value (25 kA), meaning after a fault at that level the breaker is still serviceable. For a distribution panel on a 415 V supply with available fault current up to 25 kA, this MCCB provides full coordination without needing an upstream current-limiting device. The TM-D trip unit is fixed thermal-magnetic: the thermal element (L) protects against overload at 100 A, and the magnetic element (I) handles short-circuit. No electronic adjustment or earth-leakage module is built in. The breaker is panel-mounted via backplate, occupies 2 module spaces (35 mm per module), and can be mounted horizontally or vertically. Rated insulation voltage (Ui) is 750 V, and impulse withstand (Uimp) is 8 kV — figures that confirm the breaker's internal clearances are designed for 415 V distribution systems with typical surge exposure. The toggle control type is a manual handle; no motor operator or remote trip is integrated.

Frequently asked questions

Where can I buy MGP1002L23 and get a price?

MGP1002L23 is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing — no stock or price figures are listed here.

What standard is MGP1002L23 certified to?

The MGP1002L23 is certified to BS EN 60947-2, the British/European standard for low-voltage switchgear and controlgear — circuit-breakers. It also carries suitability for isolation per that standard.

What is the closest alternative to MGP1002L23?

No official successor order code is documented for MGP1002L23. For a functionally similar current PowerPacT 4 MCCB with the same 100 A, 2-pole, 25 kA rating, consult the current Schneider PowerPacT 4 catalog — the physical footprint and trip unit may differ. Verify fit before substituting.

MPN
MGP1002L23