Skip to main content
Schneider Electric MGP1002L31 — 2-Pole MCB (DIN Rail)

MGP1002L31 PowerPacT 4 MCCB, 100A, 25kA, 2P

MPNMGP1002L31
Obsolete

Schneider Electric PowerPacT 4 molded case circuit breaker, MGP1002L31, 2-pole, 100A thermal-magnetic TM-D trip unit, 25kA Icu at 415V AC, BS EN 60947-2, toggle control, backplate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP1002L31 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP1002L31 — Electrical
ParameterValue
Rated current [In]100 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP1002L31 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP1002L31 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP1002L31 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The MGP1002L31 is a Schneider Electric PowerPacT 4 molded case circuit breaker, 2-pole configuration, rated 100 A at 40 °C with a thermal-magnetic TM-D trip unit providing LI protection (overload thermal + short-circuit magnetic). It carries a 25 kA Icu and matching 25 kA Ics at 415 V AC 50/60 Hz — the service breaking capacity equals the ultimate, so the breaker can reclose after clearing a fault at its full rating without derating. This is a Category A breaker per BS EN 60947-2, meaning it has no intentional short-time delay and is intended for distribution feeder duty, not motor-starting coordination. Panel-mounted via backplate support, accepts horizontal or vertical orientation. Two-module 35 mm footprint per pole. Rated insulation voltage 750 V, impulse withstand 8 kV — adequate for 415 V distribution panels where transient overvoltages are a concern. No earth-leakage protection integrated; this is a straight overcurrent device.

The MGP1002L31 is listed as obsolete. If you're holding a last-time-buy or need to fill an existing panel design, this is a part to secure on the next buy rather than assume indefinite supply.

Control type is toggle — manual on-off operation, no rotary handle or motor operator. Electrical durability rated at 20,000 cycles at 277 V at full rated current, 10,000 cycles at 277 V at twice rated current. Mechanical durability 20,000 cycles.

Frequently asked questions

How do I get current pricing and availability for MGP1002L31?

This part is sourced through independent distribution channels. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is MGP1002L31's listed standards (BS EN 60947-2)?

The MGP1002L31 is certified to BS EN 60947-2, the standard for low-voltage molded case circuit breakers covering construction, performance, and testing requirements.

What is MGP1002L31's listed control type?

The MGP1002L31 uses a toggle control — manual on/off switching, no rotary handle or motor operator.

MPN