Skip to main content
Schneider Electric MGP1252L12 — 2-Pole MCB (DIN Rail)

Schneider MGP1252L12 PowerPacT 4 MCCB, 125A, 2P, Obsolete

MPNMGP1252L12
Obsolete

Schneider Electric PowerPacT 4, MGP1252L12, molded case circuit breaker, 2-pole, 125A, 415V AC, 25 kA Icu, toggle control, TM-D trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP1252L12 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP1252L12 — Electrical
ParameterValue
Rated current [In]125 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP1252L12 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP1252L12 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP1252L12 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The Schneider Electric MGP1252L12 is a PowerPacT 4 molded case circuit breaker (MCCB) with a 2-pole configuration (-L2 phases), rated 125 A at 40 °C and 415 V AC 50/60 Hz. It uses a thermal-magnetic TM-D trip unit providing LI protection — thermal for overload, magnetic for short-circuit. The BS EN 60947-2 standard certifies its performance for industrial distribution panels.

Panel-mounted on a backplate, accepts horizontal or vertical orientation. The 2-module (35 mm per module) footprint fits standard DIN-rail-mount enclosures, though the breaker itself is screw-fixed to the backplate, not snap-on. Toggle control for manual on/off and trip reset.

Rated insulation voltage 750 V and impulse withstand 8 kV give headroom for distribution panels with transient surges.

Frequently asked questions

What is the breaking capacity of MGP1252L12?

The MGP1252L12 has a 25 kA Icu and Ics at 415 V AC 50/60 Hz, meaning it can safely interrupt a fault up to 25 kA without damage and be reclosed after a fault at that level.

What standard does MGP1252L12 comply with?

The MGP1252L12 is certified to BS EN 60947-2, the standard for molded case circuit breakers used in industrial distribution.

Where can I buy MGP1252L12?

As an obsolete part, MGP1252L12 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no standard stock or lead time is published.

MPN