Schneider Electric MGP1601L2 — 1-Pole MCB (DIN Rail)

MGP1601L2 PowerPacT 4 MCCB, 160A, 1P, 230V, Obsolete

MPNMGP1601L2
Obsolete

Schneider Electric PowerPacT 4, MGP1601L2, 1-pole molded case circuit breaker, 160 A at 40 °C, 230 V AC, 25 kA Icu, thermal-magnetic LI trip unit, panel-mounted, obsolete.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP1601L2 — Identification
ParameterValue
Product / component typeCircuit breaker
Poles description1P
Device applicationDistribution
MGP1601L2 — Electrical & Protection
ParameterValue
Rated current (In)160 A at 40 °C
Rated operational voltage (Ue)230 V AC 50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGP1601L2 — Mounting & Connection
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP1601L2 — Approvals
ParameterValue
Conformity standardsBS EN 60947-2
MGP1601L2 — Electrical
ParameterValue
[Ui] rated insulation voltage750 V
[Uimp] rated impulse withstand voltage8 kV

Product details

The MGP1601L2 is a 1-pole molded case circuit breaker from the Schneider Electric PowerPacT 4 range, rated 160 A at 40 °C with a thermal-magnetic LI trip unit (TM-D) that provides overload (thermal) and short-circuit (magnetic) protection for distribution circuits. Rated operational voltage is 230 V AC 50/60 Hz, with a rated insulation voltage of 750 V and impulse withstand voltage of 8 kV — the 230 V rating matches standard single-phase residential and light commercial panel voltages, while the 750 V insulation headroom covers the backplane wiring stress in a panel environment. Breaking capacity is 25 kA Icu and 25 kA Ics at 230 V AC, both equal. The breaker is panel-mounted (backplate), accepts horizontal or vertical orientation, and occupies a single 35 mm module width — the 1P form factor and narrow footprint suit it for tight single-phase subfeeds or as a main breaker in a small panel.

The part is obsolete.

The MGP1601L2 is designed and tested to BS EN 60947-2, the standard for low-voltage switchgear and controlgear circuit breakers. It is suitable for isolation per that standard, meaning it can be used as a disconnecting means in a circuit. Control is via a toggle mechanism. No earth-leakage protection is integrated — that function would need an external RCD or RCBO if required.

Frequently asked questions

Who supplies MGP1601L2 and how is it quoted for volume purchases?

The MGP1601L2 is supplied through independent distribution channels on a sourced-to-order basis. Availability and current pricing are confirmed at quote time against an RFQ.

What is MGP1601L2's listed standards (BS EN 60947-2) on this component line?

The MGP1601L2 is designed and tested to BS EN 60947-2, the standard for low-voltage switchgear and controlgear circuit breakers.

What is MGP1601L2's listed control type (Toggle) on this component line?

The MGP1601L2 uses a toggle mechanism for manual control of the circuit breaker.