Schneider Electric MGP1602L31 — 2-Pole MCB (DIN Rail)

MGP1602L31 PowerPacT 4 MCCB, 160 A, 25 kA, 2P

MPNMGP1602L31
Obsolete

Schneider Electric PowerPacT 4, MGP1602L31, 2-pole molded case circuit breaker, 160 A, 25 kA Icu at 415 V AC, thermal-magnetic trip unit TM-D.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP1602L31 — Identification
ParameterValue
Product rangePowerPacT 4
Product / component typeCircuit breaker
Device applicationDistribution
MGP1602L31 — Electrical
ParameterValue
Rated current [In]160 A at 40 °C
Pole configuration2P
Rated operational voltage [Ue]415 V AC 50/60 Hz
MGP1602L31 — Protection
ParameterValue
Suitable for isolationYes conforming to BS EN 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGP1602L31 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical
MGP1602L31 — Approvals
ParameterValue
Standards / complianceBS EN 60947-2

Product details

The MGP1602L31 is a 2-pole PowerPacT 4 molded case circuit breaker from Schneider Electric, rated 160 A at 40 °C with a 25 kA Icu/Ics breaking capacity at 415 V AC. This is a Category A breaker (no intentional short-time delay), panel-mounted, with toggle control and suitability for isolation per BS EN 60947-2.

It occupies a 2-module (35 mm per module) footprint on the panel. Phase connection is L3-. The 750 V rated insulation voltage and 8 kV impulse withstand voltage align with standard distribution panel clearances. At 160 A continuous, plan for lug or busbar sizing that matches the 40 °C base rating — no derating needed at that ambient, but a warmer enclosure will require a downward adjustment.

The breaker is rated for 20,000 mechanical cycles and 20,000 electrical cycles at rated current (277 V In/2), with 10,000 cycles at full 277 V. No earth-leakage protection is integrated. The toggle control gives a clear visual indication of trip status — useful for a field-service tech fault-isolating a downstream short.

Frequently asked questions

Where can I buy MGP1602L31?

We source the MGP1602L31 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit an RFQ for a firm commercial response.

What is the breaking capacity of MGP1602L31?

The MGP1602L31 has a 25 kA Icu (ultimate) and 25 kA Ics (service) short-circuit breaking capacity at 415 V AC, 50/60 Hz. This means it can safely interrupt a fault up to 25 kA and be used again after a fault at that level.

What standard does MGP1602L31 comply with?

The MGP1602L31 is designed and tested to BS EN 60947-2, the standard for molded case circuit breakers. It is also suitability marked for isolation per that standard.

MPN
MGP1602L31