Skip to main content
Schneider Electric MGP2504NAX — Miniature Circuit Breakers (MCB)

MGP2504NAX PowerPact 4 Switch Disconnector, 250 A, 4P, Obsol

MPNMGP2504NAX
Obsolete

Schneider Electric PowerPact 4, switch disconnector, 4P, 250 A, 415 V AC, toggle control, IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP2504NAX — Identification
ParameterValue
Product rangePowerPact
Product range (series)PowerPacT 4
Product/component typeSwitch disconnector
Device applicationIsolation
MGP2504NAX — Ratings
ParameterValue
Rated current (In)250 A
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Utilisation categoryAC-22A AC-23A DC-22A DC-23A
MGP2504NAX — Protection
ParameterValue
Earth-leakage protectionWithout
Suitability for isolationYes conforming to BS EN 60947-3
Electrical durability (cycles)15000 cycles 440 V In/2 7500 cycles 440 V In
Mechanical durability (cycles)20000 cycles
MGP2504NAX — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Contact position indicatorYes
MGP2504NAX — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to EN/IEC 60529
Pollution degree3 conforming to EN/IEC 60664-1
MGP2504NAX — Approvals
ParameterValue
StandardsBS EN 60947-3

Product details

The MGP2504NAX is a Schneider Electric PowerPact 4 switch disconnector, 4 poles, rated 250 A continuous. It's built for isolation duty per BS EN 60947-3, with a toggle handle and a visible contact position indicator. Rated operational voltage is 415 V AC; insulation voltage is 800 V AC. Utilisation categories AC-22A and AC-23A cover resistive and moderately inductive loads.

The 250 A rating is the continuous current at 415 V AC; it's sized for a 250 A panelboard or as a main isolator in a 400/630 A panelboard feeder. Short-time withstand current is 3500 A for 1 s or 3 s, and 1350 A for 20 s — that's the fault current the switch can hold closed without damage during a downstream breaker clearing. Making capacity is 4.9 kA peak, meaning it can close onto a short-circuit up to that level. IP40 keeps out tools and wires over 1 mm but not dust or water. Class II double insulation means no earth connection needed on the enclosure.

Backplate-mounted in a panel or enclosure. The 140 mm width and 161 mm height fit a standard distribution board footprint; depth is 86 mm. Toggle handle protrudes through the door. Use it as a main switch disconnector for a 250 A panelboard, or as a load-break isolator for motor control centres where the utilisation category matches the load type.

MPN
MGP2504NAX