Skip to main content
Schneider Electric MGP36600SA — Miniature Circuit Breakers (MCB)

MGP36600SA PowerPact M Unit Mount Breaker, 600A, 18kA

MPNMGP36600SA
Obsolete

Schneider Electric PowerPact M unit mount breaker, MGP36600SA, 600A, 3-pole, 18kA at 600VAC, electronic trip, shunt trip 120V, lugs off end.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP36600SA specifications
ParameterValue
Category01205 - MG, MJ UNIT MOUNT BREAKER

Product details

MGP36600SA — PowerPact M Unit Mount Breaker, 600A

The MGP36600SA is a Schneider Electric PowerPact M unit mount breaker rated 600A continuous, 3-pole, with an interrupting capacity of 18 kA at 600 VAC. It comes with an electronic trip unit, a 120V shunt trip for remote opening, and lugs off the end for line/load connections. This is a full-frame, high-current breaker sized for main or large feeder protection in switchboards, panelboards, or standalone enclosures.

600A continuous rating means this breaker carries a full 600A load without tripping under normal conditions — sized for a main disconnect or a large feeder feeding a downstream subpanel or heavy motor load center. The electronic trip unit offers adjustable long-time, short-time, and instantaneous pickup — field-configurable for coordination with downstream breakers, unlike a fixed thermal-magnetic trip.

Deployment Context

This is a unit mount breaker — it bolts into a switchboard or panelboard mounting pan, not a DIN rail. The lugs off the end accept cable or bus connections from the line side (top) and load side (bottom). The 120V shunt trip allows remote tripping from a fire alarm system, emergency stop circuit, or PLC output. Panel builders should verify lug wire range and torque specs from the PowerPact M installation guide before terminating.

Frequently asked questions

Where can I buy MGP36600SA?

We source the MGP36600SA to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — submit a request and we will quote the best option.

What is the interrupting rating of MGP36600SA?

The MGP36600SA has an interrupting capacity of 18 kA at 600 VAC. That is the maximum fault current it can safely clear at that voltage.

What category does MGP36600SA fall under?

The MGP36600SA is listed under Category 01205 — MG, MJ Unit Mount Breaker. This covers the PowerPact M and J frame unit mount breakers.

MPN
MGP36600SA