Skip to main content
Schneider Electric MGP36800SA

MGP36800SA PowerPact M 800A 3P Circuit Breaker, 65kA

MPN MGP36800SA
Obsolete

Schneider Electric PowerPact M series, MGP36800SA, 3-pole molded case circuit breaker, 800 A, electronic ET 1.0 trip unit, 65 kA AIR at 240 V AC, unit mount lugs.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGP36800SA key specifications
ParameterValue
Control typeOperating handle
Trip unit typeElectronic, basic, ET 1.0
Accessory separate part typeShunt trip 110...130 V AC/DC
Main product or component typeCircuit breaker
Voltage600 V AC 50/60 Hz UL 489
Insulation voltage ui750 V IEC 60947-2
Poles3P
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

MGP36800SA additional specifications
ParameterValue
Storage temperature-58...185 °F (-50...85 °C)
Pollution degree3 IEC 60947-1
ColorBlack
Depth8.05 in (204.47 mm)
Width8.27 in (210.06 mm)
Height12.86 in (326.64 mm)
AWG gauge3 x AWG 3/0...3 x 500 kcmil aluminium/copper
ApplicationDistribution
Operating temperature-13...158 °F (-25...70 °C)

Product details

What this 800 A PowerPact M breaker is for

The MGP36800SA is a 3-pole PowerPact M molded case circuit breaker rated 800 A continuous, built for distribution and HACR-rated applications. At 800 A, this lands in the heavy end of the PowerPact M line; it's sized for the main disconnect on a large panelboard, a switchboard feeder, or a motor control center bus.

Rated 65 kA AIR at 240 V AC, 35 kA at 480 V, and 18 kA at 600 V per UL 489. Under IEC 60947-2, the Icu is 50 kA at 240 V and 35 kA at 380/415 V.

Trip unit and adjustments

The ET 1.0 is the entry-level electronic trip in the PowerPact M family. Magnetic pickup is fixed at 1600 to 8000 A.

Mounting, wiring, and panel fit

Unit-mount lug configuration — the breaker ships with line and load lugs rated for 3 x AWG 3/0 to 3 x 500 kcmil copper or aluminum. Tightening torque is 50 N·m (442.5 lbf·in) on the main lugs.

Accessory slots and control wiring

Two slots for plug-in auxiliary switch OF modules, one slot for a plug-in alarm switch SD, and one slot for a plug-in shunt trip (MN or MX) or undervoltage release. The shunt trip listed with this part is 110 to 130 V AC/DC — verify your control voltage matches; the release coil draws steady-state current only during the trip pulse. The operating handle is the standard rotary mechanism; no motor operator is included on this base variant.

Carries UL 489, CSA, NEMA, NOM-003-SCFI-2000, and IEC 60947-2 marks. CE quality label for European installations. HACR-rated per UL — suitable for heating, air conditioning, and refrigeration equipment branch circuits where the breaker must withstand starting inrush without nuisance tripping.

MPN
MGP36800SA