Schneider Electric REL52016

Schneider Electric REL52016

MPNREL52016
Active

universal protection relay, PowerLogic P3U 3CT 1Io ringlug 4VT 16DI 8DO 48-230V DI110V RS485

$2,313.15Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

REL52016 key specifications
ParameterValue
Display typeLCD 128 x 64 pixels with single line diagram
Range of productPowerLogic P3
Product or component typeProtection relay
Switchgear diagnosis typeCT/VT supervision 60 CT supervision Trip circuit supervision TCS
Type of temperature module connectionCopper cable external module Fiber optic cable external module
Climatic withstandExposure to dry heat Bb EN/IEC 60068-2-2 Exposure to cold Ad EN/IEC 60068-2-1 Exposure to damp heat in service Db EN/IEC 60068-2-30 Exposure to damp heat in service Cab EN/IEC 60068-2-78
Power supply48...230 V AC/DC
IP degree of protectionIP54 IEC 60529
Communication portsFront USB port 1 Rear RS485 1
Communication protocolsIEC 60870-5-101 IEC 60870-5-103 DNP3 Modbus RTU DeviceNet SPAbus
Mounting case size30TE
Connections - terminalsScrew removable (digital input/output) Ring lugs removable (current transformer) Pin removable (voltage transformer)

All specifications

REL52016 additional specifications
ParameterValue
Relative humidity0...95 %, without condensation
Maximum operating altitude6561.68 ft (2000 m)
Depth8.07 in (205 mm)
Width6.7 in (170 mm)
Height6.7 in (169.5 mm)
StandardsIEC
CategoryUS1PL1S11405
Web serverEmbedded HTTP server
CybersecurityPort hardening Password protection
Number of key2 customizable
Software nameEcoStruxure Power Device ESetup Easergy Pro
Local signalling4 LEDs 8 LEDs programmable
Logs and recordsEvent recording Disturbance recording Tripping context
Measuring inputs3 1/5 A CT phase current 1 1/5 A CT residual current 4 100 V/110 V VT voltage
Control functionsSwitchgear control and monitoring Programmable switchgear interlocking Local control on single-line diagram Local control with I/O keys Local/remote control 2 function keys Mobile application with Easergy SmartApp Web-server Programmable logic
Number of sensors0 temperature sensor(s) 0 arc sensor(s)
Product referenceP3U30-6AAA2BBAA
Relay applicationUniversal
Operating threshold110...230 V AC/DC
Arc flash protectionNo
Monitoring functionsTrip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring
Protection functionsPhase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Directional earth fault 67N Transient earth fault 67NI Capacitor bank unbalance 51C Broken conductor 46 I2/I1 Cold load pick-up Switch ON to fault (SOTF) Breaker failure 50BF Directional active underpower 37P Fault locator 21FL Recloser 79 Phase undercurrent 37 Excessive starting time, locked rotor 48/51LR Motor restart inhibition 66 Capacitor overvoltage 59C Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Positive sequence undervoltage 27P Earth fault overvoltage 59N Underfrequency 81/81N Rate of change of frequency 81R Synchro-check 25 Lockout relay 86 CT supervision 60 VT supervision 60 H2 detection 68H2 H5 detection 68H5 Negative sequence overcurrent 47 Programmable stages 99 Programmable curve
Protective treatmentConformal coating
Measurement functionsCurrent 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Voltage phase to earth Voltage phase to phase Voltage zero sequence Voltage positive sequence Voltage negative sequence Voltage ratio of negative and positive Short circuit fault reactance Fault location current Earth fault reactance Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Voltage phasor diagram view Current phasor diagram view Current 2nd, 15th harmonics with THD Voltage 2nd, 15th harmonics with THD Voltage interruption Condition monitoring CB wear
Mechanical robustnessVibrations class II) IEC 60255-21-1 VibrationsFc IEC 60068-2-6 Shocks class II) IEC 60255-21-2 ShocksEa IEC 60068-2-27 Seismic tests method A class II) IEC 60255-21-3 Bumps class II) IEC 60255-21-2 BumpsEa IEC 60068-2-27
Number of setting groups4
Number of analogue inputs0
Number of analogue outputs0
Electromagnetic compatibilityEmission tests IEC/EN 60255-26 ed. 3 Emission tests CISPR 11 Emission tests CISPR 22 EMC immunity IEC/EN 60255-26 ed. 3 EMC immunity EN/IEC 61000-4-18 EMC immunity level 4 EN/IEC 61000-4-2 EMC immunity level 3 EN/IEC 61000-4-3 EMC immunity level 4 EN/IEC 61000-4-4 EMC immunity level 3 EN/IEC 61000-4-5 EMC immunity level 3 EN/IEC 61000-4-6 EMC immunity EN/IEC 61000-4-8 EMC immunity level 5 EN/IEC 61000-4-9 EMC immunity EN/IEC 61000-4-29 EMC immunity EN/IEC 61000-4-11 EMC immunity EN/IEC 61000-4-17
Number of digital inputs16
Number of digital outputs1 watchdog 8
Controllable switchgear devices4 controlled + 8 displayed
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation-40...149 °F (-40...65 °C)
MPN