Skip to main content
Schneider Electric RM4LA32M

Schneider Electric RM4LA32M Liquid Level Control Relay

MPN RM4LA32M
Obsolete

Schneider Electric Harmony Relay RM4-L series, RM4LA32M liquid level control relay, 2 C/O output contacts, 250 V AC switching voltage, adjustable time delay 0.1...10 s, three sensitivity ranges, 22.5 mm width, screw terminals.

$381.53 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

RM4LA32M specifications
ParameterValue
TypeLiquid level control relay
Insulation voltage ui500 V IEC
Current2 A 158 °F (70 °C) 24 V DC-13 IEC 60947-5-1/1991 2 A 158 °F (70 °C) 24 V DC-13 VDE 0660 3 A 158 °F (70 °C) 115 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 115 V AC-15 VDE 0660 3 A 158 °F (70 °C) 24 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 24 V AC-15 VDE 0660 3 A 158 °F (70 °C) 250 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 250 V AC-15 VDE 0660 0.1 A 158 °F (70 °C) 250 V DC-13 IEC 60947-5-1/1991 0.1 A 158 °F (70 °C) 250 V DC-13 VDE 0660 0.3 A 158 °F (70 °C) 115 V DC-13 IEC 60947-5-1/1991 0.3 A 158 °F (70 °C) 115 V DC-13 VDE 0660
IP ratingIP20 / IP50
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max65 °C
Temp operating min-20 °C
Storage temperature-40...185 °F (-40...85 °C)
Pollution degree3 IEC 60664-1
Width0.9 in (22.5 mm)
Mechanical life cycles30000000 cycles
Operating positionAny position without derating
Operating temperature-4...149 °F (-20...65 °C)

Product details

Liquid level control with three sensitivity ranges

The RM4LA32M is a liquid level control relay from the Harmony Relay RM4-L series, designed for detection by resistive probes in conductive liquid applications. It offers three selectable sensitivity scales: 0.25...5 kOhm (Low Sensitivity), 2.5...50 kOhm (Standard Sensitivity), and 25...500 kOhm (High Sensitivity), letting you match the probe circuit impedance to the fluid conductivity without external signal conditioning.

Output and timing flexibility

Two C/O (changeover) output contacts rated for switching up to 250 V AC, with a maximum switching voltage of 440 V AC. The adjustable time delay spans 0.1 to 10 seconds, giving you control over pump fill/drain sequencing or alarm debounce without an external timer module. The relay occupies 2.5 units of 9 mm pitch on a DIN rail — a 22.5 mm wide footprint that fits standard control panel layouts. Screw terminals accept 2 x 1.5 mm² flexible wire with ferrules or 2 x 2.5 mm² flexible without ferrules, with a tightening torque range of 5.3...9.7 lbf.in (0.6...1.1 N.m).

MPN
RM4LA32M