Skip to main content
Schneider Electric RM4LA32M — General Purpose Relays

Schneider Electric RM4LA32M Liquid Level Control Relay

MPNRM4LA32M
Obsolete

Schneider Electric Harmony Relay RM4-L series, RM4LA32M liquid level control relay, 2 C/O output contacts, 250 V AC switching voltage, adjustable time delay 0.1...10 s, three sensitivity ranges, 22.5 mm width, screw terminals.

$381.53Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

RM4LA32M — Identification
ParameterValue
Product/component typeIndustrial measurement and control relays
Product rangeHarmony Relay
RM4LA32M — Mechanical
ParameterValue
Width0.9 in (22.5 mm)
RM4LA32M — Environmental
ParameterValue
Ambient temperature, operation-4...149 °F (-20...65 °C)
Ambient temperature, storage-40...185 °F (-40...85 °C)
IP protection degreeIP20 IEC 60529 terminals) IP50 IEC 60529 casing)
RM4LA32M — Approvals
ParameterValue
StandardsEN/IEC 60255-6
Electromagnetic compatibility (EMC)Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2

Product details

Liquid level control with three sensitivity ranges

The RM4LA32M is a liquid level control relay from the Harmony Relay RM4-L series, designed for detection by resistive probes in conductive liquid applications. It offers three selectable sensitivity scales: 0.25...5 kOhm (Low Sensitivity), 2.5...50 kOhm (Standard Sensitivity), and 25...500 kOhm (High Sensitivity), letting you match the probe circuit impedance to the fluid conductivity without external signal conditioning.

Output and timing flexibility

Two C/O (changeover) output contacts rated for switching up to 250 V AC, with a maximum switching voltage of 440 V AC. The adjustable time delay spans 0.1 to 10 seconds, giving you control over pump fill/drain sequencing or alarm debounce without an external timer module. The relay occupies 2.5 units of 9 mm pitch on a DIN rail — a 22.5 mm wide footprint that fits standard control panel layouts. Screw terminals accept 2 x 1.5 mm² flexible wire with ferrules or 2 x 2.5 mm² flexible without ferrules, with a tightening torque range of 5.3...9.7 lbf.in (0.6...1.1 N.m).

Frequently asked questions

What sensitivity ranges does the RM4LA32M support?

Three ranges: Low Sensitivity (0.25...5 kOhm), Standard Sensitivity (2.5...50 kOhm), and High Sensitivity (25...500 kOhm). The range is selected via the front-panel switch to match the probe-to-ground resistance of the liquid being monitored.

MPN