Motor ratings and what they mean for your axis
The SH30702P0AA3100 delivers a nominal output power of 1130 W at 400 V three-phase, with a nominal torque of 15.9 lbf·in (1.8 N·m) at that same voltage — the torque figure that governs continuous-duty sizing for a pick-and-place or rotary indexing station. Peak stall torque reaches 67.3 lbf·in (7.6 N·m) across the 115-480 V three-phase range — this is the short-duration torque for acceleration or overcoming a jam, not the continuous rating; the continuous stall torque is 18.06 lbf·in (2.04 N·m) at the same voltage window.
Encoder and feedback — absolute single-turn Hiperface DSL
The absolute single-turn Hiperface DSL encoder reports position on power-up without a homing move — critical for a gantry or rotary table that must resume from the last known position after a power cycle. The rotatable right-angle connector and the quicklock straight connector give two wiring options for tight cable egress; the IP65 rating on the motor body and shaft bushing per IEC 60034-5 means the encoder and windings survive washdown in a food or packaging line, provided the mating connector is also IP65.