Active production — no obsolescence concern for this servo motor
The SH30703P1AA3000 is listed as current production, meaning it remains in Schneider Electric's active catalog with no announced end-of-life or last-time-buy window. Procurement can proceed without the urgency of a phase-out timeline. Sourced through independent distribution channels; availability and volume pricing confirmed at RFQ against the BOM quantity.
Torque and power delivery depend on supply voltage — match the drive
Nominal output power is 830 W on 230 V single-phase supply, rising to 1330 W on both 400 V and 480 V three-phase supplies. The nominal torque follows the same pattern: 2.8 Nm at 230 V single-phase, 2.1 Nm at 400 V or 480 V three-phase. This means the motor's usable torque and power are set by the available line voltage, not the motor alone. Nominal speed is 3000 rpm at 230 V single-phase, 6000 rpm at 400 V three-phase, and 7200 rpm at 480 V three-phase. Maximum mechanical speed is 8000 rpm, so the 480 V configuration runs closest to the mechanical limit.
Encoder choice locks controller compatibility — Hiperface DSL single-turn absolute
The absolute single-turn Hiperface DSL encoder provides position feedback over a digital serial link, eliminating analog sin/cos signal degradation over cable length. This encoder protocol is specific to Schneider Electric's Lexium drive family and compatible third-party controllers that support Hiperface DSL. Single-turn means absolute position within one revolution; multi-turn applications require a different encoder variant. The torque constant is 0.72 Nm/A at 120 °C copper temperature, and the back EMF constant is 49 V/krpm at 20 °C. These values define the current-to-torque relationship and the voltage-speed ceiling for the drive's DC bus.
No holding brake — plan for external brake or vertical-axis safety
Continuous stall torque is 2.94 Nm across the 115–480 V three-phase range, with a continuous stall current of 4.1 A. Peak stall torque reaches 11.3 Nm, giving a 3.8× torque overload capability for acceleration bursts — useful for cycle-time reduction in pick-and-place or indexing moves.
IP65 motor body, IP54 shaft bushing — washdown capable with a seal check
The motor body is rated IP65 per IEC 60034-5, meaning it withstands dust ingress and low-pressure water jets from any direction. The shaft bushing without the shaft seal ring drops to IP54, which is dust-protected but only splash-resistant. For washdown environments, specify the shaft seal ring option to maintain full IP65 at the shaft exit. Cooling is by natural convection — no fan or forced air. The maximum copper temperature is 130 °C, and the stator resistance is 2.7 Ω with 14.6 mH inductance. These thermal parameters set the continuous current limit in the drive's thermal model.
Mounting and shaft interface — standard flange, parallel key
Mounting uses an international standard flange with a 70 mm flange size, 60 mm centring collar diameter, and 5.5 mm mounting hole diameter. The shaft is 14 mm diameter with a 30 mm shaft length and a parallel key (5 mm key width). These dimensions match the IEC standard frame for direct coupling to gearboxes or pulleys without adapter plates. Maximum radial force is 1050 N at 1000 rpm, and maximum axial force is 160 N. These bearing load limits must be respected when selecting pulleys or belt drives to avoid premature bearing failure.