Speed and torque across the supply rail
The SH31001P0AA3100: Nominal torque sits at 2.64 N.m on 230 V single-phase, dropping to 2.27 N.m on either 400 V or 480 V three-phase — the torque constant is 0.84 N.m/A measured at 120 °C copper temperature, so the winding temperature rise under load governs the sustained output more than the supply voltage alone.
Position feedback and environmental sealing
IP65 on both the motor body and the shaft bushing per IEC 60034-5 means this motor withstands washdown without a secondary cover — the rotatable right-angle connector and the straight quicklock connector both maintain that seal, so the cable entry point does not become the wet-end weak link.
Mechanical interface and load capacity
The 100 mm flange (3.9 in) with a 95 mm centring collar and 9 mm mounting holes matches the international standard flange pattern — the smooth shaft, 19 mm diameter and 40 mm length, accepts a clamp-on coupling without a keyway, which simplifies balancing for direct-drive applications. Maximum radial force is 1930 N at 1000 rpm, derating to 1530 N at 2000 rpm and 1340 N at 3000 rpm — the bearing load envelope follows the speed, not the torque, so a belt-driven load at the upper speed band must stay within the 1340 N Fr limit to avoid premature bearing wear.
Electrical parameters and thermal behaviour
Stator resistance is 3.8 Ohm per phase with 19 mH inductance — the 12 A maximum current (Irms) sets the peak stall torque at 9.6 N.m across the 115...480 V three-phase range, while the continuous stall current of 3.5 A holds the continuous stall torque at 2.94 N.m. Natural convection cooling means no external fan — the 1190 W continuous power at 400 V three-phase relies entirely on the motor surface area and the mounting flange's thermal path to the machine frame for heat rejection.
Sourcing and lifecycle position
The SH31001P sizing reference anchors this variant in the active SH3 catalogue, so BOM positions using this order code are not under a last-time-buy window.