Skip to main content
Schneider Electric SH31402P02A2000 — Servo Motors with Brake

Schneider SH31402P02A2000 Servo Motor, 3-phase, 3000 rpm

MPNSH31402P02A2000
Active

Schneider Electric SH31402P02A2000 servo motor, three-phase, 3000 rpm, 12.3 Nm at 400 V, 3.9 kW continuous, IP54, absolute multiturn SinCos Hiperface encoder.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

SH31402P02A2000 — Identification
ParameterValue
Product typeServo motor
Holding brakeWithout

Performance

SH31402P02A2000 — Performance
ParameterValue
Nominal torque164.6 lbf.in (18.6 N.m) 115 V single phase 151.3 lbf.in (17.1 N.m) 230 V single phase 108.9 lbf.in (12.3 N.m) 400 V three phase 85.9 lbf.in (9.7 N.m) 480 V three phase
Nominal output power1460 W 115 V single phase 2690 W 230 V single phase 3860 W 400 V three phase 3660 W 480 V three phase
Continuous power3900 W
Nominal speed750 rpm 115 V single phase 1500 rpm 230 V single phase 3000 rpm 400 V three phase 3600 rpm 480 V three phase
Maximum mechanical speed4000 rpm
Continuous stall torque172.6 lbf.in (19.5 N.m) 115...480 V three phase
Peak stall torque531.9 lbf.in (60.1 N.m) 115...480 V three phase
Rotor inertia12.68 kg.cm²

Electrical

SH31402P02A2000 — Electrical
ParameterValue
Rated supply voltage (Us)115...480 V
Network phases3
PhaseThree phase
Maximum current (Irms)44.1 A
Continuous stall current13.2 A
Torque constant1.47 N.m/A 248 °F (120 °C)
Back-EMF constant101 V/krpm 68 °F (20 °C)
Number of motor poles5.0
Stator resistance0.6 Ohm
Stator inductance3.855 mH
Electrical connectionRotatable right angled connector

Feedback

SH31402P02A2000 — Feedback
ParameterValue
Encoder typeAbsolute multiturn SinCos Hiperface
Speed feedback resolution128 periods

Mechanical

SH31402P02A2000 — Mechanical
ParameterValue
Shaft end styleSmooth shaft
Shaft diameter0.9 in (24 mm)
Shaft length2.0 in (50 mm)
Motor flange size5.5 in (140 mm)
Mounting supportInternational standard flange
Length10.7 in (272.5 mm)
Number of mounting holes4
Mounting-hole diameter0.4 in (11 mm)
Mounting-hole bolt circle diameter6.5 in (165 mm)
Centring collar diameter5.1 in (130 mm)
Centring collar depth0.1 in (3.5 mm)
Maximum radial force (Fr)2240 N 1000 rpm 1780 N 2000 rpm 1550 N 3000 rpm
Maximum axial force (Fa)300 N

Environmental

SH31402P02A2000 — Environmental
ParameterValue
IP degree of protectionIP54 shaft bushing without shaft seal ring: conforming to IEC 60034-5 IP65 motor: conforming to IEC 60034-5 IP65 shaft bushing: conforming to IEC 60034-5
Cooling methodNatural convection
Winding (copper hot) temperature266 °F (130 °C)

Product details

Motor performance across supply voltages

The SH31402P02A2000: This SH3-series motor delivers different torque and speed depending on the supply configuration — a single spec number won't cover it. On three-phase 400 V it spins at 3000 rpm with 12.3 Nm nominal torque; on 480 V three-phase it reaches 3600 rpm at 9.7 Nm. For single-phase 230 V input the nominal speed drops to 1500 rpm and torque rises to 17.1 Nm. Continuous power is 3900 W, with the nominal output power varying from 1460 W on 115 V single-phase up to 3860 W on 400 V three-phase. The peak stall torque hits 60.1 Nm across the 115...480 V three-phase range — that's the short-duration overload ceiling for acceleration or hard moves.

Encoder and feedback — commissioning reality

The absolute multiturn SinCos Hiperface encoder means this motor keeps position after a power cycle — no homing routine on restart. The feedback resolution and protocol are locked to the drive's encoder card; if you're mating it to a third-party drive, confirm the Hiperface interface compatibility first.

Mounting and cooling

International standard flange, size 140 mm (5.5 in), with a centring collar diameter of 130 mm and depth of 3.5 mm. Four mounting holes on an 11 mm diameter circle. The motor is naturally convection cooled — no fan, so it relies on the machine frame or ambient airflow for heat rejection. IP54 on the shaft bushing without a shaft seal ring; IP65 on the motor body and with the shaft seal ring. For washdown environments, spec the shaft seal ring option to keep water out of the bearing cavity.

Electrical parameters and sizing

Stator resistance is 0.6 Ω, inductance 3.855 mH. Continuous stall current is 13.2 A; maximum RMS current (3 s peak) is 44.1 A. The torque constant is 1.47 N·m/A at 120 °C copper temperature — use this for drive current-loop tuning. Back EMF constant is 101 V/krpm at 20 °C — this limits the maximum achievable speed with a given DC bus voltage. The electrical connection is a rotatable right-angled connector, which helps in tight cable egress situations.

Frequently asked questions

What is SH31402P02A2000's listed phase?

Three-phase operation is listed, with nominal speeds and torques specified for 400 V and 480 V three-phase supplies. It also runs on single-phase 115 V and 230 V with reduced performance.

What is SH31402P02A2000's length?

The overall length is 10.7 inches (272.5 mm), not including the shaft extension. The shaft length is 2.0 inches (50 mm) with a 24 mm diameter.

MPN
SH31402P02A2000