Skip to main content
Schneider Electric SR2D101FU

Schneider SR2D101FU Zelio Logic Smart Relay, 6 Inputs, No Cl

MPNSR2D101FU
Active

Schneider Electric Zelio Logic compact smart relay, SR2D101FU, 100-240 V AC supply, 6 discrete inputs, relay outputs, without display or clock.

$62.23Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

SR2D101FU key specifications
ParameterValue
Protection typeAgainst inversion of terminals (control instructions not executed)
Range of productZelio Logic
Product or component typeCompact smart relay
Isolation voltage1780 V
Supply voltage limits85...264 V
Discrete input voltage100...240 V AC
Supply voltage100...240 V AC
Voltage state 0 guaranteed= 0.17 mA discrete input)
Voltage state 1 guaranteed>= 79 V discrete input
[Uimp] rated impulse withstand voltage4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Discrete input current0.6 mA
Maximum supply current30 mA 240 V without extension) 80 mA 100 V without extension)

All specifications

SR2D101FU additional specifications
ParameterValue
Current state 0 guaranteed= 10 mA 12 V relay output)
Power consumption in7 VA without extension
Supply frequency50/60 Hz
Operating rate in0.1 Hz at Ie)relay output 10 Hz no load)relay output
Discrete input frequency47...53 Hz 57...63 Hz
IP degree of protectionIP20 IEC 60529 terminal block) IP40 IEC 60529 front panel)
Connections - terminalsScrew terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid Screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid Screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
Response time50 ms ladder from state 0 to state 1)discrete input 50 ms ladder from state 1 to state 0)discrete input 50...255 ms FBD from state 0 to state 1)discrete input 50...255 ms FBD from state 1 to state 0)discrete input 10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output
Pollution degree2 IEC 61131-2
Relative humidity95 % without condensation or dripping water
Operating altitude6561.68 ft (2000 m)
Maximum altitude transport10000 ft (3048 m)
Mechanical durability10000000 cycles relay output
StandardsIEC 60068-2-27 Ea IEC 60068-2-6 Fc IEC 61000-4-12 IEC 61000-4-4 level 3 IEC 61000-4-5 IEC 61000-4-2 level 3 IEC 61000-4-11 IEC 61000-4-3 IEC 61000-4-6 level 3
ClockWithout
ChecksProgram memory on each power up
CategoryUS1000I22378
Cycle time6...90 ms
Backup time10 years 77 °F (25 °C)
Clock drift12 min/year 32...131 °F (0...55 °C) 6 s/month 77 °F (25 °C)
Local displayWithout
Tightening torque4.4 lbf.in (0.5 N.m)
Overvoltage categoryIII conforming to IEC 60664-1
Discrete input number6
Immunity to microbreaks10 ms
Environmental characteristicEMC directive conforming to IEC 61000-6-2 EMC directive conforming to IEC 61000-6-3 EMC directive conforming to IEC 61000-6-4 EMC directive conforming to IEC 61131-2 zone B Low voltage directive conforming to IEC 61131-2
Disturbance radiated (conducted)Class B EN 55022-11 group 1
Number or control scheme lines240 ladder
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation-4...104 °F (-20...40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 -4...131 °F (-20...55 °C) IEC 60068-2-1 and IEC 60068-2-2

Product details

The SR2D101FU: No built-in clock (: Without) means this unit cannot execute time-based schedules internally. If your application needs timed events, you'll need to add an external RTC module or rely on a controller upstream. Each power-up, the unit performs a program memory integrity check (: Program memory on each power up). This adds a few milliseconds to startup but ensures the logic hasn't been corrupted—useful for unattended or safety-related installations. The 10-year backup time at 25 °C means the program and data are retained without external battery—one less item to track in the spares cabinet. With six discrete inputs sensing 100–240 V AC and a cycle time of 6–90 ms, this relay is sized for simple on/off control of pumps, conveyors, or lighting panels where sub-second response is acceptable.

Frequently asked questions

Does the SR2D101FU have a real-time clock?

No, the listed clock status is 'Without'. Time-based scheduling requires an external RTC or a higher-tier Zelio Logic module.

What checks does the SR2D101FU perform on startup?

It checks program memory on each power-up to verify integrity before entering run mode.

What compliance documentation does the SR2D101FU carry?

It conforms to IEC 60068 environmental tests, IEC 61000 EMC standards at performance level 3, IEC 61131-2 for programmable controllers, and the EMC directive for class B emissions.

MPN