Schneider Electric Modicon TM5 Safety Logic Controller, TM5CSLC300FS, SERCOS III interface, SIL 3/PL e, supports 20 safety nodes, 4.3 W, 75 × 62.5 × 99 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

TM5CSLC300FS specifications
ParameterValue
Input protection typeIntegrated fuse (not interchangeable)
Main product or component typeController system
Voltage24 V -15...20 %
IP ratingIP20
Maximum cable distance between devices328.08 ft (100 m)
Temp storage max70 °C
Temp storage min-25 °C
Temp operating max45 °C
Temp operating min0 °C
Storage temperature-13...158 °F (-25...70 °C)
ColorRed
Depth3.0 in (75 mm)
Width2.5 in (62.5 mm)
Height3.9 in (99 mm)
ApplicationSafety logic controller
Operating temperature32...113 °F (0...45 °C) vertical installation) 32...131 °F (0...55 °C) horizontal installation)

Product details

Safety logic CPU for distributed SERCOS III rings

The TM5CSLC300FS is the safe logic controller within the Modicon TM5 range, handling safety-oriented control over a SERCOS III ring at 100 Mbit/s full duplex. It supports up to 20 safety nodes, each communicating on the same fiber ring, with a maximum cable distance of 100 m between stations. Rated SIL 3 per IEC 61508 and IEC 62061, PL e category 4 per ISO 13849-1. The safety reliability data shows PFD < 1E-5, PFH < 1E-9, and MTTFd > 100 years, which covers the typical demands for high-risk process and machinery safety loops. The controller draws 4.3 W from the backplane, runs fanless, and is IP20-rated. It mounts in a standard TM5 bus assembly; its envelope measures 75 mm deep, 62.5 mm wide, and 99 mm high.

Integration and environmental limits

Two shielded RJ45 ports are provided for the SERCOS III ring in and out; a memory key slot for configuration backup sits on the front face. Local diagnostics include six LEDs covering application run, debug mode, authorization, configuration, firmware, boot status, and memory key status. Operating temperature: 0 to 55 °C when mounted horizontally, 0 to 45 °C for vertical installation. Relative humidity 5 to 95% non-condensing. Maximum altitude 2000 m. Input protection is via a non-replaceable integrated fuse; reverse polarity protection is included. The controller complies with CE, EN 13849-1, IEC 61131-2, IEC 61508, IEC 61511, and IEC 62061.

MPN