Skip to main content
Schneider Electric TM5SDO4T

TM5SDO4T - Schneider Electric

MPNTM5SDO4T
Active

DISCRETE OUTPUT MODULE, MODICON

$44.45Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

TM5SDO4T key specifications
ParameterValue
Range of productModicon TM5
Product or component typeDiscrete output module
Maximum voltage drop<2 V at 500 mA sensor supply
Discrete output voltage24 V DC 20.4...28.8 V)transistor
Current per channel0.5 A
Peak output current12 A
Maximum leakage current5 µA 24 V DC when switched off
Typical current consumption20 mA 24 V DC 32 mA 5 V DC
Maximum current per output common2 A
Power dissipation in0.86 W
Switching frequency<= 500 Hz resistive
IP degree of protectionIP20

All specifications

TM5SDO4T additional specifications
ParameterValue
Electrical connection3 wires
Response time<= 300 µs from state 1 to state 0 output
Pollution degree2
Shock resistance15 gn 11 ms
Relative humidity5...95 % without condensation
Operating altitude0...6561.68 ft (0...2000 m)
Vibration resistance1 gn 8.4...150 Hz) on DIN rail 3.5 mm 5...8.4 Hz) on DIN rail
Depth3.0 in (75 mm)
Width0.5 in (12.5 mm)
Height3.9 in (99 mm)
StandardsIEC 61131-2 CSA C22.2 No 213 UL 508 CSA C22.2 No 142
MarkingCE
CategoryUS1PC1222532
Local signalling1 LED (green) for power supply 1 LED (red) for power supply 4 LEDs (yellow) for output status
Discrete output logicSource
Discrete output number4 transistor at 24 V DC
Electromagnetic compatibilityElectrostatic discharge immunity test, 4 kV on contact IEC 61000-4-2 Electrostatic discharge immunity test, 8 kV in air IEC 61000-4-2 Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz IEC 61000-4-3 Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz IEC 61000-4-3 Electrical fast transient/burst immunity test, 1 kV I/O IEC 61000-4-4 Electrical fast transient/burst immunity test, 1 kV shielded cable IEC 61000-4-4 Electrical fast transient/burst immunity test, 2 kV power lines IEC 61000-4-4 1.2/50 µs shock waves immunity test, 0.5 kV differential mode IEC 61000-4-5 1.2/50 µs shock waves immunity test, 1 kV common mode IEC 61000-4-5 Conducted RF disturbances IEC 61000-4-6 Conducted and radiated emissions CISPR 11
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation14...131 °F (-10...55 °C) without derating horizontal installation) 14...140 °F (-10...60 °C) with derating factor horizontal installation) 14...122 °F (-10...50 °C) vertical installation)
MPN
TM5SDO4T