TM5SDO8TA key specifications
ParameterValue
Range of productModicon TM5
Product or component typeDiscrete output module
Discrete output voltage24 V DC 20.4...28.8 V)
Current per channel2 A
Peak output current12 A
Maximum leakage current5 µA 24 V DC when switched off
Typical current consumption0 mA 24 V DC 44 mA 5 V DC
Maximum current per output common8 A
Power dissipation in1.5 W
Switching frequency<= 500 Hz resistive
IP degree of protectionIP20
Electrical connection1 wire

All specifications

TM5SDO8TA additional specifications
ParameterValue
Response time<= 300 µs from state 1 to state 0 output
Pollution degree2
Shock resistance15 gn 11 ms
Relative humidity5...95 % without condensation
Operating altitude0...6561.68 ft (0...2000 m)
Vibration resistance1 gn 8.4...150 Hz) on DIN rail 3.5 mm 5...8.4 Hz) on DIN rail
Depth3.0 in (75 mm)
Width0.5 in (12.5 mm)
Height3.9 in (99 mm)
StandardsIEC 61131-2 CSA C22.2 No 142 CSA C22.2 No 213 UL 508
MarkingCE
CategoryUS1PC1222532
Local signalling1 LED (green) for power supply 1 LED (red) for power supply 8 LEDs (yellow) for output status
Discrete output logicSource
Discrete output number8 transistor at 24 V DC
Electromagnetic compatibilityElectrostatic discharge immunity test, 4 kV on contact IEC 61000-4-2 Electrostatic discharge immunity test, 8 kV in air IEC 61000-4-2 Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz IEC 61000-4-3 Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz IEC 61000-4-3 Electrical fast transient/burst immunity test, 1 kV I/O IEC 61000-4-4 Electrical fast transient/burst immunity test, 1 kV shielded cable IEC 61000-4-4 Electrical fast transient/burst immunity test, 2 kV power lines IEC 61000-4-4 1.2/50 µs shock waves immunity test, 0.5 kV differential mode IEC 61000-4-5 1.2/50 µs shock waves immunity test, 1 kV common mode IEC 61000-4-5 Conducted RF disturbances IEC 61000-4-6 Conducted and radiated emissions CISPR 11
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation14...131 °F (-10...55 °C) without derating horizontal installation) 14...140 °F (-10...60 °C) with derating factor horizontal installation) 14...122 °F (-10...50 °C) vertical installation)